Isolation Power Transformers
Toroid Platform SMD PH9384.XXXNL and PM2185.XXXNL
Push Pull Converter Transformer
4KVrms Isolation (550Vrms Continuous)
Sidecar Package
UL Approved
Patented: US Pat 9,646,755
Electrical Specifications @ 25°C - Operating Temperature -40°C to +125°C
Leakage Inductance Capacitance
(1-3) with (4-6) shorted (1, 2, 3) to (4, 5, 6)
Inductance
(1-3)
(μH ±35%)
Part Number
DCR (1-3) DCR (4-6)
(Ω MAX) (Ω MAX) (V-μsec Max) (1:3) (6:4)
MAX (1-3)1
Turns Ratio Isolated Voltage
(Vrms)
Commerical
Automotive7
(μH MAX)
(pF MAX)
PH9384.011NL
PH9384.012NL
PH9384.021NL
PH9384.034NL PM2185.034NL
PH9384.035NL PM2185.035NL
PH9384.038NL PM2185.038NL
PH9384.043NL PM2185.043NL
PH9384.083NL PM2185.083NL
PH9384.089NL PM2185.089NL
PM2185.011NL
PM2185.012NL
PM2185.021NL
538
538
538
680
680
538
538
538
538
0.8
0.6
1.6
0.6
0.7
0.7
0.8
2.0
0.6
20
30
15
30
30
30
20
15
0.30
0.33
0.30
0.35
0.35
0.40
0.30
0.30
0.30
0.40
0.65
0.25
0.52
0.65
0.90
0.30
0.22
0.42
24
24
24
27
27
27
24
24
24
1CT : 1CT
1CT : 2CT
2CT : 1CT
3CT : 4CT
3CT : 5CT
3CT : 8CT
4CT : 3CT
8CT : 3CT
8CT :9CT
4000
30
Notes:
1. The ET Max is calculated to limit the core loss and temperature rise at 200KHz based on
for 130mT flux swing
a bipolar flux swing of 130mT Peak.
C. To calculate temperature rise, use the following formula:
Temperature Rise (°C) = 154 * (Core Loss(W) + Copper Loss (W))
4. The AEC-Q200 temperature and humidity operational life testing was completed using
a dielectric strength test of 4000Vdc.
5. Optional Tape & Reel packing can be ordered by adding a “T” suffix to the part number
(i.e. PH9384.012NL becomes PH9384.012NLT). Pulse complies to industry standard tape
and reel specification EIA481.
2. For Push-Pull topology, where the voltage is applied across half the primary winding
turns, the ET needs to be derated by 50% for the same flux swing.
3. The applied ET may need to be further derated for higher frequencies based on the
temperature rise which results from the core and copper losses
A. To calculate total copper loss (W), use the following formula:
Copper Loss (W) = Irms_Primary2 * DCR_Primary + Irms_
Secondary2*DCR_Secondary
6. The “NL” suffix indicates an RoHS-compliant part number.
B. To calculate total core loss (W), use the following formula:
Core Loss (W) = 2.72E-12 * (Frequency in kHz)2.43*(130 * [ET/ET Max])2.5
Where ET is the applied Volt Second, ET Max is the rated Volt Second
7. The PM2185.XXXNL part numbers are AEC-Q200 and IATF16949 certified. The mechani-
cal dimensions are 100% tested in production but do not necessarily meet aproduct
capability index (Cpk) >1.33 and therefore may not strictly conform to PPAP.
Mechanical
Schematic
PH9384.XXXNL and PM2185.XXXNL
1
2
3
6
5
4
PART NUMBER
PRIMARY
SECONDARY
Weight ...........................0.85grams
Tape & Reel ........................400/reel
Tray ......................................55/tray
Dimensions: mm
Unless otherwise specified,
all tolerances are: 0.25
power.pulseelectronics.com
http://www.power.pulseelectronics.com/contact
P775. M (01/20)
1