High Isolation Power Transformers
EP7 Platform SMD - PH9185.XXXNL and PM2190.XXXNL
Push Pull Transformer
Reinforced insulation for isolated power supply
driver
8mm creepage
5KVrms isolation (1000Vrms continuous)
7
UL and TUV certified
Electrical Specifications @ 25°C - Operating Temperature -40°C to +125°C
Inductance (1-3) Leakage Inductance DCR (1-3) DCR (4-6)
ET MAX (1-3)1
Part Number
CAP
(pF MAX)
Turns Ratio
(1:3) (6:4)
Isolated Voltage4
(Vrms)
Commercial
Automotive8
PM2190.011NL
PM2190.012NL
PM2190.013NL
PM2190.021NL
(µH 45%)
(µH MAX)
(Ω MAX)
(Ω MAX) (V-µsec MAX)
PH9185.011NL
PH9185.012NL
PH9185.013NL
PH9185.021NL
750
1.2
0.50
0.55
0.80
0.95
0.45
0.75
1.00
0.56
0.40
66
52
10.0
10.0
8.0
1CT : 1CT
1CT : 2CT
1CT : 3CT
2CT : 1CT
3CT : 4CT
3CT : 8CT
4CT : 3CT
8CT : 3CT
450
0.9
0.40
0.35
200
0.6
36
1800
750
3.0
0.75
100
66
44
89
110
10.0
10.0
8.0
5000
PH9185.034NL PM2190.034NL
PH9185.038NL PM2190.038NL
PH9185.043NL PM2190.043NL
PH9185.083NL PM2190.083NL
1.2
0.50
310
0.9
0.44
1260
2350
1.5
0.70
12.0
8.0
6.0
0.90
Notes:
1. The ET Max is calculated to limit the core loss and temperature rise at 100KHz based on a
bipolar flux swing of 180mT Peak.
C. To calculate temperature rise, use the following formula: Temperature Rise (°C) =
90 * (Core Loss(W) + Copper Loss (W))
2. For Push-Pull topology, where the voltage is applied across half the primary winding
turns, the ET needs to be derated by 50% for the same flux swing.
3. The applied ET may need to be further derated for higher frequencies based on the
temperature rise which results from the core and copper losses
4. The AEC-Q200 temperature and humidity operational life testing was completed using a
dielectric strength test of 5000Vdc.
5. Optional Tape & Reel packing can be ordered by adding a “T” suffix to the part number
(i.e. PH9185.012NL becomes PH9185.012NLT). Pulse complies to industry standard tape and
reel specification EIA481.
A. To calculate total copper loss (W), use the following formula:
Copper Loss (W) = Irms_Primary2 * DCR_Primary + Irms_Secondary2*DCR_Secondary 6. The “NL” suffix indicates an RoHS-compliant part number.
B. To calculate total core loss (W), use the following formula:
Core Loss (W) = 4.40E-10 * (Frequency in kHz)1.67 * (180 * [ET/ET Max])2.53
Where ET is the applied Volt Second, ET Max is the rated Volt Second for 180mT flux
swing
7. Continuous isolation voltage confirmed by 125°C/1000hrs accelerated aging with the bias
voltage applied between primary and secondary windings.
8. The PM2190.XXXNL part numbers are AEC-Q200 and IATF16949 certified.
9. Special Characteristics
Schematic
Mechanical
PH9185.XXXNL/PM2190.XXXNL
Weight ...................2.6grams
Tape & Reel ...............150/reel
Tray .............................80/tray
Inches
mm
Dimensions:
Unless otherwise specified,
.010
0,25
all tolerances are
power.pulseelectronics.com
http://www.power.pulseelectronics.com/contact
P708. O (02/20)