5秒后页面跳转
PM2180.083NL PDF预览

PM2180.083NL

更新时间: 2024-12-01 02:49:31
品牌 Logo 应用领域
普思电子 - PULSE /
页数 文件大小 规格书
2页 322K
描述
Isolation Power Transformers

PM2180.083NL 数据手册

 浏览型号PM2180.083NL的Datasheet PDF文件第2页 
Isolation Power Transformers  
Toroid Platform SMD PH9085.XXXNL and PM2180.XXXNL  
Push Pull Converter Transformer  
Functional insulation for isolated power supply driver  
2.5KVrms isolation (380Vrms continuous)  
Electrical Specifications @ 25°C - Operating Temperature -40°C to +125°C  
Inductance  
(1-3)  
(µH 35%)  
Leakage Inductance  
(1-3) with (4-6) shorted (1, 2, 3) to (4, 5, 6)  
Capacitance  
Isolated  
Voltage2  
(Vrms)  
Part Number  
Commerical  
Automotive6  
DCR (1-3)  
(Ω MAX)  
DCR (4-6)  
(Ω MAX) (V-µsec Max)  
ET MAX (1-3)1  
Turns Ratio  
(1:3) (6:4)  
(µH MAX)  
0.8  
(pF MAX)  
PH9085.011NL PM2180.011NL  
PH9085.012NL PM2180.012NL  
PH9085.021NL PM2180.021NL  
PH9085.034NL PM2180.034NL  
PH9085.035NL PM2180.035NL  
PH9085.038NL PM2180.038NL  
PH9085.043NL PM2180.043NL  
PH9085.083NL PM2180.083NL  
PH9085.089NL PM2180.089NL  
1020  
1020  
1160  
1020  
1020  
1020  
1160  
1160  
1160  
30  
40  
20  
40  
40  
40  
30  
15  
0.60  
0.85  
0.60  
0.60  
0.80  
0.85  
0.60  
0.60  
0.60  
0.65  
1.60  
0.35  
0.75  
1.20  
2.00  
0.50  
0.30  
0.70  
22  
22  
1CT : 1CT  
1CT : 2CT  
2CT : 1CT  
3CT : 4CT  
3CT : 5CT  
3CT : 8CT  
4CT : 3CT  
8CT : 3CT  
8CT :9CT  
0.6  
1.6  
23.6  
22  
0.6  
0.6  
22  
2500  
0.7  
22  
0.8  
23.6  
23.6  
23.6  
2.0  
0.6  
40  
Notes:  
1. The ET Max is calculated to limit the core loss and temperature rise at 100KHz based on a  
bipolar flux swing of 210mT Peak.  
swing  
C. To calculate temperature rise, use the following formula: Temperature Rise (°C)  
= 340 * (Core Loss(W) + Copper Loss (W))  
4. The AEC-Q200 temperature and humidity operational life testing was completed using a  
dielectric strength test of 2750Vdc.  
5. Continuous isolation voltage confirmed by 125°C/1000hrs accelerated aging with the bias  
voltage applied between primary and secondary windings.  
6. The PM2180.XXXNL part numbers are AEC-Q200 and IATF16949 certified. The mechanical  
dimensions are 100% tested in production but do not necessarily meet aproduct capability  
index (Cpk) >1.33 and therefore may not strictly conform to PPAP.  
2. For Push-Pull topology, where the voltage is applied across half the primary winding turns,  
the ET needs to be derated by 50% for the same flux swing.  
3. The applied ET may need to be further derated for higher frequencies based on the  
temperature rise which results from the core and copper losses  
A. To calculate total copper loss (W), use the following formula:  
Copper Loss (W) = Irms_Primary2 * DCR_Primary + Irms_Secondary2*DCR_Secondary  
B. To calculate total core loss (W), use the following formula:  
Core Loss (W) = 7.70E-13 * (Frequency in kHz)2.43 * (210 * [ET/ET Max])2.5  
Where ET is the applied Volt Second, ET Max is the rated Volt Second for 210mT flux  
Mechanical  
Schematic  
PH9085.XXXNL and PM2185.XXXNL  
Weight ...........................0.365grams  
Tape & Reel ........................700/reel  
Tray ......................................55/tray  
Dimensions: mm  
Unless otherwise specified,  
all tolerances are±0.25  
power.pulseelectronics.com  
http://www.power.pulseelectronics.com/contact  
P721. G (11/18)  
1

与PM2180.083NL相关器件

型号 品牌 获取价格 描述 数据表
PM2180.089NL PULSE

获取价格

Isolation Power Transformers
PM2180.XXXNL PULSE

获取价格

Isolation Power Transformers
PM2185.011NL PULSE

获取价格

Isolation Power Transformers
PM2185.012NL PULSE

获取价格

Isolation Power Transformers
PM2185.021NL PULSE

获取价格

Isolation Power Transformers
PM2185.034NL PULSE

获取价格

Isolation Power Transformers
PM2185.035NL PULSE

获取价格

Isolation Power Transformers
PM2185.038NL PULSE

获取价格

Isolation Power Transformers
PM2185.043NL PULSE

获取价格

Isolation Power Transformers
PM2185.083NL PULSE

获取价格

Isolation Power Transformers