THROUGH HOLE CURRENT
SENSE TRANSFORMERS
VDE Approved
Meets IEC950 insulation requirements
3750VRMS primary to secondary
breakdown voltage
Frequency range 10kHz to 200kHz
V
D E
Electrical Specifications @ 25°C — Operating Temperature -40°C to 130°C
DCR
Part
Number
IPK
(Amps)
RT
(Ω)
Droop
(%)
KVI
LS
Turns
(NS 1%)
REQ
(mΩ)
RS
KB
KCL
(Volt/Amp) (mH MIN)
(Ω MAX)
PE-67050
PE-67100
PE-67200
PE-67300
35
37
38
37
15
56
2.4
2.2
2.0
2.2
0.30
0.56
1.00
1.70
5.0
20
0.70
1.40
4.50
11.0
50
.269x106
51.2x10-6
.95
.85
.82
.84
100
200
300
.0671x106 1.56x10-6
.0168x106 47.3x10-9
.00746x106 6.13x10-9
200
510
80
180
NOTES:
1. These current sense transformers have a 1 turn primary winding, secondary
turns (Ns) as indicated in the table, and a 130°C insulation system.
6. The core loss factor (KCL) is valid from 10kHz to 200kHz at 105°C.
7. The terminating resistor (R
droop, or scale factor (KVI).
T) may be varied to adjust operating flux (BOP),
2. The reference values are for unipolar operation, 50kHz, 40% duty factor, and
an estimated 55°C temperature rise.
8. The scale factor (KVI) is proportional to the terminating resistor (R
equal to 1 volt/amp when R =N
9. The secondary inductance (L ) is measured at 15kHz and .5V for PE-67050,
T) and is
3. The maximum useable peak sense current (IPK) depends on temperature rise
or core saturation, which should be evaluated for the operating conditions.
T
S.
S
4. These Current Sense Transformers are recommended for switch mode
power supply applications, unipolar or bipolar, operating at frequencies from
10kHz to 200kHz.
1V for PE-67100, 2V for PE-67200 and 3V for PE-67300.
10. To order RoHS compliant part, add the suffix “NL” to the part number (i.e.
PE-67050 becomes PE-67050NL).
5. The maximum recommended operating flux density (BOP) is 2000 gauss to
prevent saturation at an operating temperature of 105°C.
Mechanical
Schematic
.750
19,05
.200
5,08
.400
10,16
MIN
MAX
.565
14,35
MAX
3
.041 .002
(2 X)
±
1,04 0,05
1
2
NS TURNS
4
1 TURN
3
1
4
.600
15,24
.750
19,05
MAX
2
Parts per package . . . . . . . . . . .80
Inches
mm
Dimensions:
.051 .003
±
(2 X)
.005
0,13
1,30 0,08
Unless otherwise specified, all tolerances are
For More Information:
Pulse Worldwide
Headquarters
Pulse
Pulse China Headquarters
B402, Shenzhen
Tech-Innovation International
Tenth Kejinan Rd.
High-Tech Industrial Park
Nanshan District, Shenzhen
China
Pulse North China Pulse South Asia Pulse North Asia
Room 1503
150 Kampong Ampat
#07-01/02
No. 26
Europe
12220 World Trade Dr. Einsteinstrasse 1
XinYin Building
No. 888 YiShan Rd.
Shanghai 200233
China
Kao Ching Rd.
Yang Mei Chen
Tao Yuan Hsien
Taiwan, R. O. C.
San Diego, CA 92128
U.S.A.
www.pulseeng.com
D-71083 Herrenberg
Germany
KA Centre
Singapore 368324
Tel: 858 674 8100
Fax: 858 674 8262
Tel: 49 7032 7806 0
Fax: 49 7032 7806 12 Fax: 86 755 33966700
Tel: 86 755 33966678
Tel: 86 21 54643211/2 Tel: 65 6287 8998
Fax: 86 21 54643210
Fax: 65 6280 0080
Tel: 886 3 4641811
Fax: 886 3 4641911
Performance warranty of products offered on this data sheet is limited to the parameters specified. Data is subject to change without notice. Other brand and product
names mentioned herein may be trademarks or registered trademarks of their respective owners. © Copyright, 2007. Pulse Engineering, Inc. All rights reserved.
www.pulseeng.com
P577.A (5/07)