OM1326SMM
OM1326NKM
OM1326NMM OM1326STM OM1326SRM
OM1326N2M
OM1326NTM
1.5 AMP POSITIVE ADJUSTABLE VOLTAGE
REGULATOR APPROVED TO DESC DRAWING 7703407
Three Terminal, Precision Adjustable
Positive Voltage Regulator In Hermetic
Style Packages (LM117AHV)
Please see mechanical
outlines herein
FEATURES
• Similar To Industry Standard LM117AHV
• Approved To DESC Standardized Military Drawing Number 7703407
• Built In Thermal Overload Protection
• Short Circuit Current Limiting
• Available In Six Package Styles
• Maximum Output Voltage Tolerance Is Guaranteed to + 1%
DESCRIPTION
These three terminal positive regulators are supplied in hermetically sealed
packages. All protective features are designed into the circuit, including thermal
shutdown, current-limiting, and safe-area control. With heat sinking, these devices
can deliver up to 1.5 Amps of output current. The LCC-20 device is limited to 0.5
Amps. The unit also features output voltages that can be fixed from 1.2 Volts to 57
Volts using external resistors.
ABSOLUTE MAXIMUM RATINGST @ 25°C
c
Power Dissipation
LCC-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 W
Case-All Others. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 W
Input - Output Voltage Differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Lead Temperature (Soldering 10 seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . 300°C
Thermal Resistance, Junction to Case:
3.3
LCC-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17°C/W
TO-257 (Isol), SMD-3 and SMD 257. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2°C/W
TO-257 (Non-Isol) and SMD-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W
TO-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.0°C/W
Maximum Output Current:
LCC-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 A
Case-All Others. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5A
Recommended Operating Conditions:
Output Voltage Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.2 to 57 VDC
Ambient Operating Temperature Range (TA). . . . . . . . . . . . . . . . - 55°C to + 125°C
Input Voltage Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 to 61.25 VDC
1 08 R3
Supersedes 4 11 R2
3.3 - 25