Nexperia
NMUX1308-Q100
1.5 V to 5.5 V, 8-channel analog switch multiplexer and demultiplexer with injection-current control
10. Recommended operating conditions
Table 6. Recommended operating conditions
Symbol Parameter
Conditions
Min
1.5
0
Typ
Max
5.5
5.5
VCC
5.5
50
Unit
V
VCC
VI
supply voltage
input voltage
switch voltage
-
-
-
-
-
E, S0, S1, S2
V
VSW
Yn, Z; enable and disable mode
Yn, Z; VCC = 0 V
0
V
0
V
ISW
switch current
Yn, Z; VSW > GND or VSW < VCC
Tamb = -40 °C to +85 °C
;
;
-50
mA
Yn, Z; VSW > GND or VSW < VCC
Tamb = -40 °C to +125 °C
-25
-
25
mA
ISK
switch clamping current Yn, Z; VSW < GND or VSW > VCC
ground current
[1]
-50
-100
-25
-
-
-
-
-
50
100
50
mA
mA
mA
mA
°C
IGND
IINJ
injected current
single off switch
all off switches combined
-100
-40
100
+125
Tamb
ambient temperature
[1] If the VSW > VCC or if VSW < GND, the pin will be shunted to GND through an internal FET. The current must be limited within the
specified value.
11. Static characteristics
Table 7. Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground 0 V); for test circuit see Fig. 5.
Symbol Parameter
Conditions
25 °C
-40 °C to +85 °C -40 °C to +125 °C Unit
Min Typ Max
Min
Max
Min
Max
Analog switch
RON
ON resistance
VI = VCC to GND;
ISW = 0.5 mA; E = VIL;
see Fig. 5
VCC = 1.8 V ± 10%
VCC = 2.5 V ± 10%
VCC = 3.3 V ± 10%
VCC = 5 V ± 10%
450 1151
-
-
-
-
1245
419
262
167
-
-
-
-
1245
436
278
178
Ω
Ω
Ω
Ω
-
-
-
-
160 388
95 231
60 146
ΔRON
ON resistance
mismatch
between
VI = 0.5VCC; ISW = 0.5 mA;
E = VIL
VCC = 1.8 V ± 10%
VCC = 2.5 V ± 10%
VCC = 3.3 V ± 10%
VCC = 5 V ± 10%
-
-
-
-
5
4
2
1
91
35
17
11
-
-
-
-
91
39
19
11
-
-
-
-
91
41
19
12
Ω
Ω
Ω
Ω
channels
©
NMUX1308_Q100
All information provided in this document is subject to legal disclaimers.
Nexperia B.V. 2024. All rights reserved
Product data sheet
Rev. 1.1 — 21 February 2024
7 / 23