RoHS
NKET135 Series RoHS
Nell High Power Products
ELECTRICAL SPECIFICATIONS
VOLTAGE RATINGS
VRRM/VDRM, MAXIMUMREPETITIVE VRSM/VDSM, MAXIMUM NON-REPETITIVE
IRRM/IDRM
TYPE
VOLTAGE
CODE
PEAK REVERSE VOLTAGE
V
PEAK REVERSE VOLTAGE
V
AT 125 °C
NUMBER
mA
08
12
14
16
800
900
1200
1400
1600
1300
1500
1700
NKET135..A
20
FORWARD CONDUCTION
PARAMETER
SYMBOL
TEST CONDITIONS
VALUE
135
UNITS
A
Maximum average on-state current
lT(AV)
180° conduction, half sine wave ,50Hz
at case temperature
85
°C
lT(RMS)
Maximum RMS on-state current
212
180° conduction, half sine wave ,50Hz ,TJ = 85°C
t = 10 ms
3800
3980
3192
3343
72.2
65.7
50.9
46.4
No voltage
reapplied
t = 8.3 ms
Maximum peak, one-cycle, on-state
lTSM
non-repetitive surge current
A
t = 10 ms
100%VRRM
reapplied
t = 8.3 ms
Sine half wave,
initial TJ = TJ maximum
t = 10 ms
No voltage
reapplied
t = 8.3 ms
2
Maximum I t for fusing
2
kA s
2
I t
t = 10 ms
100%VRRM
reapplied
t = 8.3 ms
2
2
2
kA √s
t = 0.1 ms to 10 ms, no voltage reapplied
√
t
Maximum I
√
722
t for fusing
I
Maximum on-state voltage drop
VTM
1.65
ITM = 405A, TJ = 25 °C, 180° conduction
V
Maximum holding current
IH
Anode supply = 12 V initial IT = 30 A, TJ= 25 °C
40~150
mA
Anode supply = 12 V resistive load = 1Ω
Gate pulse: 10 V, 100 μs, TJ = 25 °C
IL
Maximum latching current
400
BLOCKING
PARAMETER
SYMBOL
TEST CONDITIONS
VALUE
UNITS
Maximum peak reverse and
off-state leakage current
IRRM
,
mA
TJ = 125 °C
20
IDRM
50 Hz, circuit to base,
2500 (1min)
3500 (1s)
VISO
V
RMS isolation Voltage
all terminals shorted
Critical rate of rise of
off-state voltage
TJ = TJ maximum,
dV/dt
V/μs
800
exponential to 67 % rated VDRM
Page 2 of 4