NET1 SERIES
Designed to meet the stringent requirements of today’s high-speed
Advanced surface-mount design and packing technology reduce the
NET1’s height to 1.35” (34.3mm) to fit in 1U applications. NET1’s
high-performance active power factor circuitry meets EN61000-3-2
requirements for compliance with European Power Line Harmonic
Requirements for 2001. A multifunctional output terminal allows
connection to #8 ring lugs, 0.25” quick disconnects, cable connectors,
and PCB-mounted connectors.
datacom and telecom circuitry, Power-One’s NET1 series is an excellent
compact power solution for low-voltage, high-current applications. The
NET1’s high efficiency is achieved through the use of synchronous
rectification and a newly-patented “Soft Transition Forward Converter”.
The NET1’s rectification method lowers output losses, reduces system
cooling requirements (allowing greater power in a smaller package), and
eliminates minimum load requirements.
FEATURES
•
•
•
•
•
•
•
Currents Over 100 Amps
Fits 1U Chassis Height Constraints
No Minimum Load Requirement
Current Share Capabilities on All Outputs
Patented High-Efficiency Design
Meets European Power Factor Requirements for 2001
Excellent Load Transient Response
MULTIPLE OUTPUT MODEL SELECTION CHART – 240W WITH 300 LFM FORCED AIR COOLING
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%Pk-Pk (NOTE 2)
INITIAL SETTING
ACCURACY
MODEL
+3.3V
+2.5V
+5V
+12V
+1.8V
+3.3V
+5V
+0.5V
+0.5V
FIXED
FIXED
+0.5V
+0.5V
FIXED
FIXED
50A
50A
5A
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
1%
1%
3%
3%
1%
1%
3%
3%
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
30mV
30mV
30mV
100mV
20mV
30mV
30mV
100mV
NET1-4325
4A
50A
50A
5A
NET1-4130
NET1-4112
+12V
4A
+1.8V
+1.65V
+5V
+0.5V
+0.5V
FIXED
FIXED
50A
50A
5A
0.2%
0.2%
0.2%
0.2%
1%
1%
3%
3%
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
20mV
30mV
30mV
100mV
+12V
4A
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
85
47
20
TYP
MAX
264
63
UNITS
Input Voltage - AC
Input Frequency
Hold-up Time
Continuous input range.
AC input.
After last AC line peak at 240 watts.
85 VAC at full rated load.
VAC
Hz
mS
Input Current
4.0
ARMS
Input Protection
Inrush Surge Current
Power Factor
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 220 VAC, one cycle, 25°C.
Per EN61000-3-2.
35
APK
W/VA
0.95
Rev. 11/2000
1