35W Triple Output Switching Power Supply
NET-35 series
Features :
Universal AC input / Full range
Protections: Short circuit / Over load / Over voltage
Cooling by free air convection
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL
NET-35A
NET-35B
NET-35C
NET-35D
OUTPUT NUMBER
CH1
5V
CH2
12V
1A
CH3
-5V
CH1
5V
CH2
12V
1A
CH3
-12V
0.5A
CH1
5V
CH2
15V
1A
CH3
-15V
0.5A
CH1
5V
CH2
24V
0.5A
CH3
12V
1A
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
3A
0.5A
3A
2.5A
2.5A
Note.6 0.5 ~ 4A 0.1 ~ 1.5A 0.1 ~ 0.5A 0.5 ~ 4A 0.1 ~ 1.5A 0.1 ~ 0.5A 0.5 ~ 3.5A 0.1 ~ 1.5A 0.1 ~ 0.5A 0.5 ~ 3.5A 0.1 ~ 1A 0.1 ~ 1A
29.5W 33W 35W 36.5W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 80mVp-p 120mVp-p 120mVp-p 80mVp-p 150mVp-p 150mVp-p 80mVp-p 200mVp-p 120mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION Note.4 0.5%
LOAD REGULATION Note.5 1.5%
OUTPUT
CH1:4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
6.0%
1.0%
3.0%
6.0%
1.0%
3.0%
2.0%
0.5%
1.5%
6.0%
1.0%
3.0%
6.0%
1.0%
3.0%
2.0%
0.5%
1.5%
8.0%
1.0%
3.0%
8.0%
1.0%
3.0%
2.0%
0.5%
1.5%
8.0%
1.0%
3.0%
8.0%
1.0%
3.0%
SETUP, RISE TIME
500ms, 30ms/230VAC
1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
50ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
10ms/115VAC at full load
120 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
78%
79%
79%
79%
INPUT
0.75A/115VAC
COLD START 45A
<2mA / 240VAC
0.5A/230VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
PROTECTION
ENVIRONMENT
SAFETY &
OVER VOLTAGE
WORKING TEMP.
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 45
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1) Approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
EMC
(Note 6)
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1 Light industry level, criteria A
MTBF
386.2Khrs min. MIL-HDBK-217F (25
99*97*36mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
0.36Kg; 45pcs/17.2Kg/0.93CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:NET-35-SPEC 2006-12-27