50W Triple Output Switching Power Supply
NET-50 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL
NET-50A
NET-50B
NET-50C
NET-50D
OUTPUT NUMBER
CH1
5V
CH2
12V
2A
CH3
-5V
CH1
5V
CH2
12V
2A
CH3
-12V
0.5A
CH1
5V
CH2
15V
1.5A
CH3
-15V
0.5A
CH1
5V
CH2
24V
1A
CH3
12V
1A
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
4A
0.5A
4A
4A
3A
Note.6 0.6 ~ 5A 0.2 ~ 2.5A 0.1 ~ 0.7A 0.6 ~ 5A 0.2 ~ 2.5A 0.1 ~ 0.7A 0.6 ~ 5A 0.1 ~ 2A 0.1 ~ 0.7A 0.6 ~ 5A 0.1 ~ 1.5A 0.1 ~ 1.5A
46.5W 50W 50W 51W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 80mVp-p 120mVp-p 120mVp-p 80mVp-p 150mVp-p 150mVp-p 80mVp-p 200mVp-p 120mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION Note.4 0.5%
LOAD REGULATION Note.5 1.5%
OUTPUT
CH1:4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
6.0%
1.0%
3.0%
5.0%
1.0%
1.0%
2.0%
0.5%
1.5%
6.0%
1.0%
3.0%
5.0%
1.0%
1.0%
2.0%
0.5%
1.5%
8.0%
1.0%
3.0%
5.0%
1.0%
1.0%
2.0%
0.5%
1.5%
8.0%
1.0%
3.0%
6.0%
1.0%
3.0%
SETUP, RISE TIME
500ms, 30ms/230VAC
1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
50ms/230VAC
10ms/115VAC at full load
120 ~ 370VDC
85 ~ 264VAC
47 ~ 63Hz
76%
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
78%
78%
80%
INPUT
1.1A/115VAC
0.65A/230VAC
COLD START 45A
<2mA / 240VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
PROTECTION
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 45
)
TEMP. COEFFICIENT
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1) approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
ISOLATION RESISTANCE
EMC
(Note 7)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A
HARMONIC CURRENT
EMS IMMUNITY
MTBF
348.4K hrs min. MIL-HDBK-217F (25
129*98*38mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.44Kg; 45pcs/21Kg/1.24CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:NET-50-SPEC 2010-10-18