Axial Lead Reed Switches
High Power > MRPR-20
MRPR-20 20.3mm Miniature High Voltage and High Power Reed Switch
RoHS
Description
The MRPR-20 Reed Switch is a miniature, normally open switch with a 20.32mm
long x 2.84mm diameter (0.800” x 0.112”) glass envelope, capable of high
voltage and power switching of 265Vac at 50VA. The MRPR-20 has high
insulation resistance of 1010 ohms minimum and contact resistance less than
100 milli-ohms.
Features
• Miniature normally open switch
• Capable of switching 265Vac or
1.5A at up to 50W/VA
• Available sensitivity range
17-43 AT
• Minimum breakdown voltage
750Vdc
Agency Approvals
Benefits
Ampere-Turns
Range
• Hermetically sealed switch
contacts are not affected by and
have no effect on their external
environment
• Zero operating power required
for contact
• High voltage and power switching
with a miniature switch
Agency
Agency File Number
E47258
17-43 AT
Note: Contact Littelfuse for specific agency approval ratings.
Applications
• Reed relays (suitable for switching
global mains voltage)
• Limit switching
• Telecom line switching
• Heavy Load Switching
Dimensions
Dimensions in mm (inch)
0.63
(.025) DIA. REF.
CL OF OVERLAP
28.32
(1.115) REF.
Switch Type
2.84
(.112) MAX.
Contact Form
A (SPST-NO)
Body: Glass
Leads: Tin-plated Ni-Fe wire
Materials
18.16
(.715) MAX.
20.32
(.800) MAX.
Note: SPST-NO = Single-pole, single-throw, normally open
56.64
(2.230) NOM.
Electrical Ratings
Contact Rating 1
W/VA - max.
50
Switching 2
Vdc - max.
Vac - max.
Vdc - min.
250
265
750
Voltage 3
Current 3
Breakdown 4
Switching 2
Adc - max.
Aac - max.
Adc - max.
1.5
1.1
3.0
Carry
Contact, Initial
Insulation
Ω - max.
Ω - min.
0.100
1010
Resistance
Capacitance
Temperature
Notes:
Contact
pF - typ.
0.2
Operating
Storage 5
°C
°C
-20 to +125
-65 to +125
1. Contact rating - Product of the switching voltage and current should never exceed the wattage rating. Contact Littelfuse for additional load/life information.
2. When switching inductive and/or capacitive loads, the effects of transient voltages and/or currents should be considered. Refer to Application Notes AN108A and AN107 for details.
3. Electrical Load Life Expectancy - Contact Littelfuse with voltage, current values along with type of load.
4. Breakdown Voltage - per MIL-STD-202, Method 301.
5. Storage Temperature - Long time exposure at elevated temperature may degrade solderability of the leads.
© 2016 Littelfuse
Revised: 04/26/16
littelfuse.com
Specifications are subject to change without notice.