CABLES - CAVI
MR-PK
MR-QK
Rubber, rubber insulation, RN-F series,
HAR approved
Gomma, isolante gomma, serie RN-F,
omologato HAR
Description. Conductor insulation: EI4 rubber. Outer sheath: EM2 rubber.
Descrizione. Isolante conduttori: gomma EI4. Guaina esterna: gomma EM2.
Impiego. Adatto per ambienti secchi e umidi, uso permanente in ambienti interni ed esterni.
Omologato con marchio HAR (Armonizzazione Europea) fino a 5 conduttori. Resistenza
alla fiamma: IEC 60332-1. Buona resistenza a oli, acqua e intemperie. Buona resistenza
all’abrasione.
Application. Suitable for wet and dry environments, permanent outdoor and indoor use.
Approved with HAR mark (European Harmonization) up to 5 wires. Flame resistance degree:
IEC 60332-1. Good resistance to oils, water and weather. Good resistance to abrasion.
Max working voltage: 300/500 V up to 1,00 mm2 and 450/750 V over.
Test voltage: 2000 V up to 1,00 mm2 and 2500 V over, according to norms.
Tensione massima di lavoro: 300/500 V fino a 1,00 mm2 e 450/750 V oltre.
Tensione di prova: 2000 V fino a 1,00 mm2 e 2500 V oltre, secondo norme.
Note to table:
(a) example: 3 = three wires; 2+1 = two wires + yellow/green earth.
(b) colours: A = brown, blue, black, white, grey; yellow/green earth if present.
B = brown, grey, black, blue; green/yellow earth if present.
(c) HAR cable construction classification.
Note alla tabella:
(a) esempio: 3 = tre conduttori; 2+1 = due conduttori + terra giallo/verde.
(b) colori: A = marrone, blu, nero, bianco; giallo/verde terra se presente.
B = marrone, grigio, nero, blu; giallo/verde terra se presente.
(c) classificazione HAR della costruzione del cavo.
Formation
Descriptive code
Short
code
Refer. or style
Sheath colour Wires
Copper Static
Dynamic
Note Nota
Formazione
Codice descrittivo
Rifer. o style
Colore guaina
colour class
application application
Codice
breve
Colore
cond.
Classe
rame
Applicazione Applicazione
statica
dinamica
n x mm2 (a)
2x0,75
(c)
RAL
(b)
IEC 60228 °C
°C
MR-PK9
MR-PK95-02XA5
RN-F HAR
RN-F HAR
RN-F HAR
RN-F HAR
RN-F HAR
RN-F HAR
RN-F HAR
RN-F HAR
RN-F HAR
RN-F HAR
RN-F HAR
RN-F HAR
RN-F HAR
RN-F
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
A
A
B
B
A
A
B
B
A
A
B
B
B
N
N
N
N
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
-30...+ 60
(2+1)x0,75
MR-PK95-03GA5 536
MR-PK95-03XB5
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
-30...+ 60
3x0,75
(3+1)x0,75
2x1,00
MR-PK95-04GB5 5R2
MR-PK96-02XA5
(2+1)x1,00
3x1,00
MR-PK96-03GA5 6R1
MR-PK96-03XB5
(3+1)x1,00
2x1,50
MR-PK96-04GB5 6R2
MR-PK97-02XA5
(2+1)x1,50
3x1,50
MR-PK97-03GA5 7R1
MR-PK97-03XB5
(3+1)x1,50
(4+1)x1,50
(6+1)x1,50
(9+1)x1,50
(11+1)x1,50
(18+1)x1,50
MR-PK97-04GB5 7R2
MR-PK97-05GB5 7R5
MR-PK97-07GN5 7R6
MR-PK97-10GN5
RN-F
MR-PK97-12GN5 769
MR-PK97-19GN5
RN-F
RN-F
PUR, rubber insulation, BQ-F series,
HAR approved, cold resistant (- 40°C)
PUR, isolante gomma, serie BQ-F,
omologato HAR, resistente al freddo (- 40°C)
Description. Conductor insulation: EI6 rubber. Sheath of matt halogen free polyether
polyurethane (PUR).
Descrizione. Isolante conduttori: gomma EI6. Guaina in poliuretano (PUR) polietere opaco
senza alogeni.
Application. Suitable for wet and dry environments, permanent indoor and outdoor use even at
very low temperature. Approved with HAR mark (European Harmonization). Good resistance to
oils, water and weather. Good resistance to abrasion, tearing and cutting. Good flexibility at low
temperature down to -40°C.
Impiego. Adatto per ambienti secchi e umidi, uso permanente in ambienti interni ed esterni
anche a tempertature molto basse. Omologato con marchio HAR (Armonizzazione Europea).
Buona resistenza a oli, acqua e intemperie. Buona resistenza a abrasione, taglio e lacerazione.
Buona flessibilità a basse temperature fino a -40°C.
Max working voltage: 300/500 V up to 1,00 mm2 and 450/750 V.
Test voltage: 2000 V up to 1,00 mm2 and 2500 V over, according to norms.
Tensione massima di lavoro: 300/500 V fino a 1,00 mm2 e 450/750 V oltre.
Tensione di prova: 2000 V fino a 1,00 mm2 e 2500 V oltre, secondo norme.
Note to table:
Note alla tabella:
(a) example: 3 = three wires; 2+1 = two wires + yellow/green earth.
(b) colours: A = brown, blue, black, white, grey; yellow/green earth if present.
B = brown, grey, black, blue; green/yellow earth if present.
(c) HAR cable construction classification.
(a) esempio: 3 = tre conduttori; 2+1 = due conduttori + terra giallo/verde.
(b) colori: A = marrone, blu, nero, bianco; giallo/verde terra se presente.
B = marrone, grigio, nero, blu; giallo/verde terra se presente.
(c) classificazione HAR della costruzione del cavo.
Formation
Descriptive code
Short
code
Refer. or style
Sheath colour Wires
Copper Static
Dynamic
Note Nota
Formazione
Codice descrittivo
Rifer. o style
Colore guaina
colour class
application application
Codice
breve
Colore
cond.
Classe
rame
Applicazione Applicazione
statica
dinamica
n x mm2 (a)
2x0,75
(c)
RAL
(b)
IEC 60228 °C
°C
MR-QK9
MR-QK95-02XA5
BQ-F HAR
BQ-F HAR
BQ-F HAR
BQ-F HAR
BQ-F HAR
BQ-F HAR
BQ-F HAR
BQ-F HAR
BQ-F HAR
BQ-F HAR
BQ-F HAR
BQ-F HAR
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
A
A
B
B
A
A
B
B
A
A
B
B
5
5
5
5
5
5
5
5
5
5
5
5
-40...+ 80
(2+1)x0,75
MR-QK95-03GA5 5R3
MR-QK95-03XB5
-40...+ 80
-40...+ 80
-40...+ 80
-40...+ 80
-40...+ 80
-40...+ 80
-40...+ 80
-40...+ 80
-40...+ 80
-40...+ 80
-40...+ 80
3x0,75
(3+1)x0,75
2x1,00
MR-QK95-04GB5 5R4
MR-QK96-02XA5
(2+1)x1,00
3x1,00
MR-QK96-03GA5 6R3
MR-QK96-03XB5
(3+1)x1,00
2x1,50
MR-QK96-04GB5 6R4
MR-QK97-02XA5
(2+1)x1,50
3x1,50
MR-QK97-03GA5 7R3
MR-QK97-03XB5
(3+1)x1,50
MR-QK97-04GB5 7R4
33 MR-P
www.shield.net