mps-30 ꢀerieꢀ
30W Single Output for Medical Type
ꢏꢃꢆꢍꢌꢄꢃꢅꢈꢛ
�ꢀꢁꢂꢃꢄꢅꢆꢇꢈꢉꢊꢈꢁꢀꢋꢌꢍꢈꢎꢈꢏꢌꢇꢇꢈꢄꢆꢀꢐꢃ
ꢑꢒꢓꢈꢇꢃꢆꢔꢆꢐꢃꢈꢕꢌꢄꢄꢃꢀꢍ ꢖꢗꢘꢙꢉ
ꢚꢄꢒꢍꢃꢕꢍꢁꢒꢀꢅꢛꢜꢝꢒꢄꢍꢈꢕꢁꢄꢕꢌꢁꢍꢎꢞꢂꢃꢄꢈꢇꢒꢆꢟꢎꢞꢂꢃꢄꢈꢂꢒꢇꢍꢆꢐꢃꢎꢞꢂꢃꢄꢈꢍꢃꢙꢋꢃꢄꢆꢍꢌꢄꢃ
ꢏꢁꢠꢃꢟꢈꢅꢓꢁꢍꢕꢝꢁꢀꢐꢈꢡꢄꢃꢢꢌꢃꢀꢕꢣꢈꢆꢍꢈꢤꢖꢖꢥꢦꢧ
ꢑꢒꢓꢈꢕꢒꢅꢍ
ꢦꢁꢐꢝꢈꢄꢃꢇꢁꢆꢨꢁꢇꢁꢍꢣ
ꢘꢈꢣꢃꢆꢄꢅꢈꢓꢆꢄꢄꢆꢀꢍꢣ
SPECIFICATION
MODEL
MPS-30-5
MPS-30-12
MPS-30-15
MPS-30-24
MPS-30-27
MPS-30-48
DC�VOLTAGE
5V
12V
15V
24V
27V
48V
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
5A
2.5A
2A
1.2A
1.1A
0.6A
0�~�5A
25W
0�~�2.5A
30W
0�~�2A
30W
0�~�1.2A
28.8W
240mVp-p
3.0%
0�~�1.1A
29.7W
240mVp-p
3.0%
0�~�0.6A
28.8W
240mVp-p
2.0%
RIPPLE�&�NOISE�(max.) Note.2 80mVp-p
VOLTAGE�TOLERANCE Note.3 3.0%
120mVp-p
3.0%
150mVp-p
3.0%
0.5%
1.0%
OUTPUT
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISE�TIME
HOLD�TIME (Typ.)
1.0%
2.0%
1.0%
0.5%
0.5%
0.5%
1.0%
1.0%
1.0%
1.0%
500ms,�30ms/230VAC����������500ms,�30ms/115VAC�at�full�load
70ms/230VAC����������12ms/115VAC�at�full�load
88�~�264VAC�auto�switch����������120�~�370VDC
47�~�63Hz
VOLTAGE�RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
72%
75%
76%
77%
78%
78%
INPUT
0.8A/115VAC����������0.5A/230VAC
COLD�START 30A/230VAC
<0.3mA /�264VAC
AC�CURRENT (Typ.)
INRUSH�CURRENT (Typ.)
LEAKAGE�CURRENT
Above�105% rated�output�power
OVER�LOAD
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
5.5�~�6.75V 13.2�~�16.2V 16.5�~�20.25V 26.4�~�32.4V
29.7�~�36.45V
52.8�~�64.8V
PROTECTION OVER�VOLTAGE
Protection�type�: Shut�down�o/p�voltage,�re-power�on�to�recover
Tj�135 typically�(U1)�Detect�on�main�control�IC
OVER�TEMPERATURE
Protection�type�:�Shut�down�o/p�voltage,�recovers�automatically�after�temperature�goes�down
-10�~�+60 (Refer�to�output�load�derating�curve)
20�~�90%�RH non-condensing
WORKING�TEMP.
WORKING�HUMIDITY
-20�~�+85 ,�10�~�95%�RH
ENVIRONMENT STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
0.03%/ (0�~�50
10�~�500Hz,�2G�10min./1cycle,�Period�for�60min.each�along�X, Y,�Z�axes
VIBRATION
UL2601-1, TUV�EN60601-1,�IEC601-1 Approved
I/P-O/P:4KVAC�����I/P-FG:1.5KVAC�����O/P-FG:SHORT
I/P-O/P,�I/P-FG:100M�Ohms/500VDC
SAFETY STANDARDS
WITHSTAND�VOLTAGE
ISOLATION�RESISTANCE
EMI�CONDUCTION�&�RADIATION
HARMONIC�CURRENT
EMS�IMMUNITY
SAFETY &
Compliance�to�EN55011�(CISPR11)�Class�B
EMC
(Note�4)
Compliance�to�EN61000-3-2,-3
Compliance�to EN61000-4-2,3,4,5,6,8,11;�ENV50204,�EN55024,�EN60601-1-2�Medical�level,�criteria A
MTBF
547Khrs�min.������MIL-HDBK-217F�(25
101.6*65.8*23.5mm�(L*W*H)
)
OTHERS
NOTE
DIMENSION
0.16Kg;�90pcs/15.8Kg/1.02CUFT
PACKING
ꢤꢗꢈꢉꢇꢇꢈꢋꢆꢄꢆꢙꢃꢍꢃꢄꢅꢈꢩꢞꢪꢈꢅꢋꢃꢕꢁꢆꢇꢇꢣꢈꢙꢃꢀꢍꢁꢒꢀꢃꢟꢈꢆꢄꢃꢈꢙꢃꢆꢅꢌꢄꢃꢟꢈꢆꢍꢈꢫꢘꢖꢬꢉꢊꢈꢁꢀꢋꢌꢍꢭꢈꢄꢆꢍꢃꢟꢈꢇꢒꢆꢟꢈꢆꢀꢟꢈꢫꢮ ꢒꢡꢈꢆꢙꢨꢁꢃꢀꢍꢈꢍꢃꢙꢋꢃꢄꢆꢍꢌꢄꢃꢗ
ꢫꢗꢈꢯꢁꢋꢋꢇꢃꢈꢰꢈꢀꢒꢁꢅꢃꢈꢆꢄꢃꢈꢙꢃꢆꢅꢌꢄꢃꢟꢈꢆꢍꢈꢫꢖꢱꢦꢧꢈꢒꢡꢈꢨꢆꢀꢟꢓꢁꢟꢍꢝꢈꢨꢣꢈꢌꢅꢁꢀꢐꢈꢆꢈꢤꢫꢲꢈꢍꢓꢁꢅꢍꢃꢟꢈꢋꢆꢁꢄꢳꢓꢁꢄꢃꢈꢍꢃꢄꢙꢁꢀꢆꢍꢃꢟꢈꢓꢁꢍꢝꢈꢆꢈꢖꢗꢤꢌꢡꢈꢰꢈꢴꢵꢌꢡꢈꢋꢆꢄꢆꢇꢇꢃꢇꢈꢕꢆꢋꢆꢕꢁꢍꢒꢄꢗ
ꢘꢗꢈꢪꢒꢇꢃꢄꢆꢀꢕꢃꢈꢛꢈꢁꢀꢕꢇꢌꢟꢃꢅꢈꢅꢃꢍꢈꢌꢋꢈꢍꢒꢇꢃꢄꢆꢀꢕꢃꢭꢈꢇꢁꢀꢃꢈꢄꢃꢐꢌꢇꢆꢍꢁꢒꢀꢈꢆꢀꢟꢈꢇꢒꢆꢟꢈꢄꢃꢐꢌꢇꢆꢍꢁꢒꢀꢗ
ꢴꢗꢈꢪꢝꢃꢈꢋꢒꢓꢃꢄꢈꢅꢌꢋꢋꢇꢣꢈꢁꢅꢈꢕꢒꢀꢅꢁꢟꢃꢄꢃꢟꢈꢆꢈꢕꢒꢙꢋꢒꢀꢃꢀꢍꢈꢓꢝꢁꢕꢝꢈꢓꢁꢇꢇꢈꢨꢃꢈꢁꢀꢅꢍꢆꢇꢇꢃꢟꢈꢁꢀꢍꢒꢈꢆꢈꢡꢁꢀꢆꢇꢈꢃꢢꢌꢁꢋꢙꢃꢀꢍꢗꢈꢪꢝꢃꢈꢡꢁꢀꢆꢇꢈꢃꢢꢌꢁꢋꢙꢃꢀꢍꢈꢙꢌꢅꢍ ꢨꢃꢈꢄꢃꢳꢕꢒꢀꢡꢁꢄꢙꢃꢟꢈꢍꢝꢆꢍꢈꢁꢍꢈꢅꢍꢁꢇꢇꢈꢙꢃꢃꢍꢅ
ꢶꢱꢊꢈꢟꢁꢄꢃꢕꢍꢁꢂꢃꢅꢗ
300 myleꢀ standiꢀh Blvd., Taunton, mA 02780
WWW.AsTRODYNE.COm
ph: 1-800-823-8082
Fax: 508-823-8181