30W Single Output for Medical Type
MPS-30 series
Features :
Universal AC input / Full range
Low leakage current 0.3mA
Protections: Short circuit / Overload / Over voltage / Over temperature
Fixed switching frequency at 100KHz
Low cost
High reliability
3 years warranty
SPECIFICATION
MODEL
MPS-30-5
MPS-30-12
MPS-30-15
MPS-30-24
MPS-30-27
MPS-30-48
DC VOLTAGE
5V
12V
15V
24V
27V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
5A
2.5A
2A
1.2A
1.1A
0.6A
0 ~ 5A
25W
0 ~ 2.5A
30W
0 ~ 2A
30W
0 ~ 1.2A
28.8W
240mVp-p
3.0%
0 ~ 1.1A
29.7W
240mVp-p
3.0%
0 ~ 0.6A
28.8W
240mVp-p
2.0%
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3 3.0%
120mVp-p
3.0%
150mVp-p
3.0%
0.5%
1.0%
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
1.0%
1.0%
0.5%
0.5%
0.5%
2.0%
1.0%
1.0%
1.0%
1.0%
500ms, 30ms/230VAC
500ms, 30ms/115VAC at full load
70ms/230VAC
12ms/115VAC at full load
VOLTAGE RANGE
88 ~ 264VAC auto switch
47 ~ 63Hz
120 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
72%
75%
0.5A/230VAC
76%
77%
78%
78%
INPUT
0.8A/115VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
COLD START 30A/230VAC
<0.3mA / 264VAC
LEAKAGE CURRENT
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.5 ~ 6.75V 13.2 ~ 16.2V 16.5 ~ 20.25V 26.4 ~ 32.4V
OVERLOAD
29.7 ~ 36.45V
52.8 ~ 64.8V
PROTECTION OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Tj 135 typically (U1) detect on main control IC
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to "Derating Curve")
OVER TEMPERATURE
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
VIBRATION
ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:SHORT
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, medical level, criteria A
547Khrs min. MIL-HDBK-217F (25
101.6*65.8*23.5mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.16Kg; 90pcs/15.8Kg/1.02CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:MPS-30-SPEC 2011-12-27