Spec No.: JELF243A_0119K-01
P1/9
CHIP COILS (CHIP INDUCTORS) LQH2HPN□□□□JR□ REFERENCE SPECIFICATION
1. Scope
This reference specification applies to chip coils (chip inductors) LQH2HPN_JR series for general electronic equipment.
2. Part Numbering
(Ex.)
LQ
H
2H
P
N
220
M
J
R
L
Product ID Structure Dimension Application and Category Inductance Tolerance Dimension Other
Packaging
L: ø180 taping
*B: bulk
(L × W)
*B: Bulk packing is also available.
3. Part Number and Rating
characteristic
(T)
Operating temperature range (ambient temperature not including self-temperature rise)
(product temperature including self-temperature rise)
Storage temperature range
-40°C to +105°C
-40°C to +125°C
-40°C to +105°C
Rated current
(mA)*3
Inductance
DC
resistance
(Ω)
Self-resonant
frequency
(MHz min.)
Based on temperature
rise*2
Customer
Part number
Murata
Part number
Nominal
value
(μH)
Based on
inductance
change*1
Tolerance
(%)
Ambient
Ambient
temperature temperature
85°C
2750
2400
2070
1810
1650
1420
1290
1000
830
105°C
1650
1440
1240
1080
990
LQH2HPNR47NJRL
LQH2HPN1R0NJRL
LQH2HPN1R2NJRL
LQH2HPN1R5NJRL
LQH2HPN2R2MJRL
LQH2HPN3R3MJRL
LQH2HPN4R7MJRL
LQH2HPN6R8MJRL
LQH2HPN100MJRL
LQH2HPN150MJRL
LQH2HPN220MJRL
0.47
1.0
1.2
1.5
2.2
3.3
4.7
6.8
10
N: ±30
N: ±30
N: ±30
N: ±30
0.031±20%
0.048±20%
0.055±20%
0.075±20%
190
120
100
95
3500
2600
2450
2200
1700
1450
1230
1050
830
M: ±20 0.092±20%
50
M: ±20
M: ±20
M: ±20
M: ±20
M: ±20
M: ±20
0.13±20%
0.17±20%
0.26±20%
0.38±20%
0.55±20%
0.84±20%
45
850
40
770
35
600
30
490
15
20
690
710
420
22
20
530
540
320
*1 When rated current is applied to the products, inductance will be within ±30% of initial inductance value range.
*2 When rated current is applied to the products, temperature rise caused by self-generated heat shall be limited to 40°C max
(ambient temperature 85°C max).
When rated current is applied to the products, temperature rise caused by self-generated heat shall be limited to 20°C max
(ambient temperature 85°C to 105°C).
*3 Keep the temperature (ambient temperature plus self-generation of heat) under 125°C.
4. Testing Conditions
Unless otherwise specified
Temperature: ordinary temperature (15°C to 35°C)
Humidity: ordinary humidity [25% to 85% (RH)]
In case of doubt
Temperature: 20°C±2°C
Humidity: 60% to 70% (RH)
Atmospheric pressure: 86 kPa to 106 kPa
MURATA MFG CO., LTD