Spec No.: JELF243A_9128G-01
P1/8
CHIP COILS (CHIP INDUCTORS) LQH2HPZ□□□□GR□
Murata Standard Reference Specification [AEC-Q200]
1. Scope
This reference specification applies to chip coils (chip inductors) LQH2HPZ_GR series for automotive electronics based on
AEC-Q200 except for power trains and safeties.
2. Part Numbering
(Ex.)
LQ
H
2H
P
Z
1R0
M
G
R
L
Product ID Structure Dimension Application and Category Inductance Tolerance Dimension Other
Packaging
L: ø180 taping
*B: bulk
(L × W)
*B: Bulk packing is also available.
3. Part Number and Rating
characteristic
(T)
Operating temperature range (ambient temperature not including self-temperature rise)
(product temperature including self-temperature rise)
Storage temperature range
-40°C to +105°C
-40°C to +125°C
-40°C to +125°C
Rated current
(mA)*3
Inductance
Self-resonant
frequency
(MHz min.)
Based on temperature
rise*2
Customer
Part number
Murata
Part number
DC resistance
ESD
5 A: 8 kV
Nominal
value
(μH)
Based on
inductance
change*1
(Ω)
Tolerance
(%)
Ambient
Ambient
temperature temperature
85°C
2520
2330
2100
1850
1470
1100
1000
860
105°C
1470
1350
1200
1110
850
LQH2HPZR47MGRL 0.47
LQH2HPZR68MGRL 0.68
LQH2HPZ1R0MGRL 1.0
LQH2HPZ1R5MGRL 1.5
LQH2HPZ2R2MGRL 2.2
LQH2HPZ3R3MGRL 3.3
LQH2HPZ4R7MGRL 4.7
LQH2HPZ6R8MGRL 6.8
±20
±20
±20
±20
±20
±20
±20
±20
±20
±20
±20
0.045±20%
0.055±20%
0.068±20%
0.087±20%
0.134±20%
0.225±20%
0.300±20%
0.395±20%
0.560±20%
0.925±20%
1.360±20%
120
110
100
90
2900
2430
2130
1700
1550
1230
1090
830
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
80
70
660
50
570
40
490
LQH2HPZ100MGRL
LQH2HPZ150MGRL
LQH2HPZ220MGRL
10
15
22
30
700
710
430
20
570
560
310
15
460
430
250
*1 When rated current is applied to the products, inductance will be within ±30% of initial inductance value range.
*2 When rated current is applied to the products, temperature rise caused by self-generated heat shall be limited to 40°C max
(ambient temperature 85°C max).
When rated current is applied to the products, temperature rise caused by self-generated heat shall be limited to 20°C max
(ambient temperature 85°C to 105°C).
*3 Keep the temperature (ambient temperature plus self-generation of heat) under 125°C.
4. Testing Conditions
Unless otherwise specified
Temperature: ordinary temperature (15°C to 35°C)
Humidity: ordinary humidity [25% to 85% (RH)]
In case of doubt
Temperature: 20°C±2°C
Humidity: 60% to 70% (RH)
Atmospheric pressure: 86 kPa to 106 kPa
MURATA MFG CO., LTD