Spec No.: JELF243A_9129G-01
P1/8
CHIP COILS (CHIP INDUCTORS) LQH2HPZ□□□□JR□
Murata Standard Reference Specification [AEC-Q200]
1. Scope
This reference specification applies to chip coils (chip inductors) LQH2HPZ_JR series for automotive electronics based on
AEC-Q200 except for power trains and safeties.
2. Part Numbering
(Ex.)
LQ
H
2H
P
Z
220
M
J
R
L
Product ID Structure Dimension
(L × W)
Application and
characteristic
Category Inductance Tolerance Dimension Other
(T)
Packaging
L: ø180 taping
*B: bulk
*B: Bulk packing is also available.
3. Part Number and Rating
Operating temperature range
(ambient temperature not including self-temperature rise)
(product temperature including self-temperature rise)
-40°C to +105°C
-40°C to +125°C
-40°C to +105°C
Storage temperature range
Rated current
(mA)*3
Inductance
Self-resonant
DC resistance
Customer
Part number
Murata
Part number
Based on temperature rise*2
ESD
5 A: 8 kV
frequency
Nominal
value
(μH)
Based on
inductance
change*1
(Ω)
Tolerance
(%)
Ambient
Ambient
(MHz min.)
temperature temperature
85°C
2750
2400
2070
1810
1650
1420
1290
1000
830
105°C
1650
1440
1240
1080
990
LQH2HPZR47NJRL 0.47
N: ±30 0.031±20%
N: ±30 0.048±20%
N: ±30 0.055±20%
N: ±30 0.075±20%
M: ±20 0.092±20%
190
120
100
95
3500
2600
2450
2200
1700
1450
1230
1050
830
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
LQH2HPZ1R0NJRL
LQH2HPZ1R2NJRL
LQH2HPZ1R5NJRL
LQH2HPZ2R2MJRL
LQH2HPZ3R3MJRL
LQH2HPZ4R7MJRL
LQH2HPZ6R8MJRL
LQH2HPZ100MJRL
LQH2HPZ150MJRL
LQH2HPZ220MJRL
1.0
1.2
1.5
2.2
3.3
4.7
6.8
10
50
M: ±20
M: ±20
M: ±20
M: ±20
M: ±20
M: ±20
0.13±20%
0.17±20%
0.26±20%
0.38±20%
0.55±20%
0.84±20%
45
850
40
770
35
600
30
490
15
20
690
710
420
22
20
530
540
320
*1 When rated current is applied to the products, inductance will be within ±30% of initial inductance value range.
*2 When rated current is applied to the products, temperature rise caused by self-generated heat shall be limited to 40°C max
(ambient temperature 85°C max).
When rated current is applied to the products, temperature rise caused by self-generated heat shall be limited to 20°C max
(ambient temperature 85°C to 105°C).
*3 Keep the temperature (ambient temperature plus self-generation of heat) under 125°C.
4. Testing Conditions
Unless otherwise specified
Temperature: ordinary temperature (15°C to 35°C)
Humidity: ordinary humidity [25% to 85% (RH)]
In case of doubt
Temperature: 20°C±2°C
Humidity: 60% to 70% (RH)
Atmospheric pressure: 86 kPa to 106 kPa
MURATA MFG CO., LTD