KMA210
NXP Semiconductors
Programmable angle sensor
KMA210
V
DD
Z
Z
O(pl)
O(pl)
OUT/DATA
GND
008aaa259
Fig 4. Equivalent output circuit in case of a power-loss condition
Table 4 describes the power-loss behavior and gives the resulting output voltage
depending on the interrupted supply or ground line and the load resistance.
Table 4.
Power-loss behavior
Load resistance
Interrupted supply line
Interrupted ground line
RL(ext) > 5 k
VO 4 %VDD
VO 96 %VDD
7.4 Broken bond wire detection
The broken bond wire detection circuit enables the detection of an interrupted supply or
ground line of the MR sensor bridge. In the case of a broken bond wire the device goes
into diagnostic mode and a status bit is set.
7.5 Low supply voltage detection and overvoltage protection
If the supply voltage is below the switch-off threshold voltage, a status bit is set and the
device goes into diagnostic mode. If the supply voltage is above the overvoltage switch-on
threshold voltage, the device enters diagnostic mode. Table 5 describes the system
behavior depending on the voltage range of the supply voltage.
Table 5.
System behavior
Supply voltage
State
Description
0 V to 1.8 V
start-up power The output buffer drives an active LOW or is powered down,
but the switches of the power-loss detection circuit are not
fully opened and set the output to a level between ground and
half the supply voltage.
1.8 V to VPOR
power-on
reset
The power-loss charge pump is fully operational and turns the
switches of the detection circuit off. The output buffer drives
an active LOW and sets the output to the lower diagnostic
level. During the reset phase all circuits are in reset and/or
Power-down mode.
VPOR to Vth(on) or initialization
Vth(off)
The digital core and the oscillator are active. After reset the
content of the non-volatile memory is copied into the shadow
registers. The output buffer drives an active LOW and sets the
output to the lower diagnostic level.
Vth(on) or Vth(off) to functional
All analog circuits are active and the measured angle is
available at the analog output. Not all parameters are within
the specified limits.
minimum VDD
operation
KMA210
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2011. All rights reserved.
Product data sheet
Rev. 2 — 7 December 2011
7 of 37