Document 901
For Microchip Grid-Connected
Flyback Transformers Solar Microinverter using dsPIC
• Listed on Bill of Material for Reference Design AN1338
• Input voltage: 22 Vdc – 55 Vdc
• 3000 Vrms, one minute isolation from primary to secondary
windings
Core material Ferrite
Terminations RoHS tin-silver (96.5/3.5) over tin over nickel over phos
bronze. Other terminations available at additional cost.
Weight 94.3 g
Ambient temperature –40°C to +85°C
Storage temperature Component: –40°C to +85°C.
Tray packaging: –40°C to +80°C
Resistance to soldering heat Max three 40 second reflows at
+260°C, parts cooled to room temperature between cycles
Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C /
85% relative humidity)
Failures in Time (FIT) / Mean Time Between Failures (MTBF)
38 per billion hours / 26,315,789 hours, calculated per Telcordia SR-332
Packaging 20 per tray
PCB washing Tested with pure water or alcohol only. For other solvents,
see Doc787_PCB_Washing.pdf
Inductance
at0A1
±±0ꢀ(µH)
Leakage
inductance3
max (µH)
DCR max (Ohms)2
Part
number
SRF typ
(kHz)
Turns ratio4
pri:sec
Isat5
(A)
pri
sec
Output
JA4635-AL
KA4823-CL
28
28
0.008
0.008
0.106
0.472
640
360
0.138
0.115
1:6
1:12
10.5
10.5
110 Vac
220 Vac
1. Inductance is measured at 150 kHz, 0.1 Vrms.
2. DCR is with the secondary windings connected in parallel.
3. Leakage inductance is for the three windings of the primary with the
secondary windings shorted.
4. Turns ratios are with the primary and secondary windings connected in
parallel.
5. DC current at which the inductance drops 10% (typical) from its value
without current.
6. Electrical specifications at 25°C.
Refer to Doc 362 “Soldering Surface Mount Components” before soldering.
inches
mm
Dimensions are in
Document 901 Revised 10/11/11
US +1-847-639-6400 sales@coilcraft.com
UK +44-1236-730595 sales@coilcraft-europe.com
Taiwan +886-2-2264 3646 sales@coilcraft.com.tw
China +86-21-6218 8074 sales@coilcraft.com.cn
Singapore + 65-6484 8412 sales@coilcraft.com.sg
© Coilcraft Inc. 2014
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.