EZ-LIGHT Touch Gen 2 K50 FDA-Grade
Specialty Pick-to-Light
Datasheet
Compact, Single-Point Devices for Error-Proofing of Bin-Picking Operations
•
•
•
FDA-grade materials; rated to IEC IP67, IP68, and IP69K
Laser marked information withstands aggressive cleaning procedures
Excellent immunity to false triggering by water spray, detergents, oils, and other
foreign materials
•
Rugged, cost-effective and easy-to-install solutions for error-proofing and parts-
verification applications
•
•
•
•
Compact devices are completely self contained—No controller needed
Easy actuation—no force required
12 V to 30 V dc operation
Can be actuated with bare hands or in gloves
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Models
Indicators
1
2
Model
Function
Output
Connection
Job
Mis-Pick
Sense
K50APT2FGRYC3QP
K50RPT2FGRYC3QP
K50APT2FGRYC4QP
•
•
•
Job light always On with job input until
touched
Touch activates output and overrides job
light with sense light
Touch with inactive job input activates mis-
pick light and activates output
PNP, N.O.
Green
Red
Yellow
PNP, N.C.
PNP, N.O.
150 mm (6 in)
PVC cable with
a 5-pin M12/
Euro-style
male, stainless
steel, quick
disconnect
•
•
Job light always On with job input until
touched
Touch activates output and overrides job
light with sense light until job input is
removed
Touch with inactive job input activates mis-
pick light for 5 seconds after touched and
activates output
(QD)
Green
Red
Yellow
K50RPT2FGRYC4QP
PNP, N.C.
•
Indicator and Output Behavior
NOTE: "C3" and "C4" models as referenced in the table pertain to a part of the product model number, immediately preceding
the designation.
Output Signal
Sensor Conditions
Hand/pick absent
C3 Models
On Green
C4 Models
Status
On Green
Off
Job input active
Hand/pick present
Hand/pick absent
On Yellow
Off
On Yellow until job input is removed
Off
On
No job input
Off
1
•
To order the 2 m (6.5 ft) PVC cable model, omit the suffix "QP" in the model number. For example, K50APT2FGRYC3.
•
To order the 150 mm (6 in) PUR cable model with a 5-Pin M12/Euro-style quick disconnect, replace the suffix "QP" with "QPMA" in the
model number. For example, K50APT2FGRYC3QPMA.
•
Models with a quick disconnect require a mating cordset.
2
PNP models only are listed. For other output types, contact Banner Engineering.
Original Document
189838 Rev. D
27 July 2016
189838