EZ-LIGHT Touch Gen 2 K50 Series Pick-to-Light
Datasheet
Compact, Single-Point Devices for Error-Proofing of Bin-Picking Operaꢀons
•
•
Excellent immunity to false triggering by water spray, detergents, oils, and other foreign
materials
Rugged, cost-eꢀecꢁve and easy-to-install soluꢁons for error-proofing and parts-
verificaꢁon applicaꢁons
•
•
•
•
•
•
Compact devices are completely self contained—no controller needed
Waterproof IEC IP69K construcꢁon for washdown environments
Easy actuaꢁon—no force required
12 V dc to 30 V dc operaꢁon
Can be actuated with bare hands or gloves
Compact models available for lower profile applicaꢁons
Standard Model
Compact Model
WARNING: Not To Be Used for Personnel Protecꢀon
Never use this device as a sensing device for personnel protecꢀon. Doing so could lead to serious injury or death. This device
does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applicaꢁons. A sensor failure
or malfuncꢁon can cause either an energized or de-energized sensor output condiꢁon.
Models
1
Model
Funcꢀon
Output
Connecꢀon
Job Light
K50APT2GXDQ
K50RPT2GXDQ
K50ANT2GXDQ
K50RNT2GXDQ
K50APT2GRCQ
K50RPT2GRCQ
K50ANT2GRCQ
K50RNT2GRCQ
K50APT2GREQ
K50RPT2GREQ
K50ANT2GREQ
K50RNT2GREQ
PNP, N.O.
PNP, N.C.
NPN, N.O.
NPN, N.C.
PNP, N.O.
PNP, N.C.
NPN, N.O.
NPN, N.C.
PNP, N.O.
PNP, N.C.
NPN, N.O.
NPN, N.C.
•
•
Job light is illuminated at all ꢁmes while job input is acꢁve
Touch acꢁvates output
Green
•
•
Job light is Green while job input is acꢁve
Touch acꢁvates output and overrides job light (turns Red) for visual
verificaꢁon that acꢁon was sensed
Integral 4-pin M12/Euro-
style male quick
Green (Red)
Green (Red)
disconnect (QD)
•
•
•
Job light is Green at all ꢁmes while job input is acꢁve
Touch acꢁvates output
A touch while job input is inacꢁve causes unit to light Red, providing
visual verificaꢁon that sensor is funcꢁoning properly
Wiring Diagrams
NPN
PNP
Color Key
1
3
1 = Brown
2 = White
3 = Blue
1
+
+
12-30V dc
–
12-30V dc
–
3
4
2
4 = Black
4
2
Load
Load
Job Light
Enable > 7V dc
Job Light
Enable < 1.0V dc
Note: Cabled wiring diagrams are shown. Quick disconnect (QD) wiring diagrams are funcꢁonally idenꢁcal.
1
•
•
•
To order the 2 m (6.5 ꢂ) PVC cable model, omit the suffix "Q" in the model number. For example, K50APT2GXD.
To order a compact model, add the suffix "C'" aꢂer K50 in the model number. For example, K50CAPT2GXDQ.
Models with a quick disconnect require a maꢁng cordset.
Original Document
189828 Rev. D
23 June 2017
189828