VDE
SMALL SIZED
POWER RELAY
JZ-RELAYS
14
.551
FEATURES
22
.866
• Small sized flat type: 22×14×11.6 mm .866×.551×.457 inch
• High dielectric withstanding: 10,000 V surge in µs between coil and contact
• High electrical noise immunity
11.6
.457
• High sensitivity type available
• VDE,TÜV, SEMKO also approved
mm inch
SPECIFICATIONS
Contact
Characteristics
(at 25°C 77°F, 50% Relative humidity)
Standard
type
High
Standard
TV-5 High
Max. operating speed
Initial insulation resistance*1 Min. 100 MΩ at 500 V DC
20 cpm
Type
sensitivity type TV-5 type sensitivity type
Arrangement
1 Form A
Between open
contacts
750 Vrms for 1 min.
2,000 Vrms for 1 min.
Min. 10,000 V
Initial
Contact material
Silver alloy
breakdown
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Between
contacts and coil
voltage*2
100 mΩ
5 A 125 V AC 3 A 125 V AC 8 A 125 V AC 8 A 125 V AC
5 A 30 V DC 3 A 30 V DC 5 A 30 V DC 5 A 30 V DC
Surge voltage between
contact and coil*3
Nominal switching capacity
Rating
(resistive)
Max. switching power
150 W, 750 VA 90 W, 500 VA 150 W, 1,250 VA 150 W, 1,000 VA
Operate time*4
(at nominal voltage)
Release time*4
(without diode)
Approx. 4 ms
Max. switching voltage
250 V AC, 110 V DC (0.3 A)
Max. switching current
5 A
105
3 A
8 A
Approx. 2 ms
Mechanical (at 180 cpm)
Expected
life (min.
5 × 106
(at nominal voltage)
2 ×105
105
5 ×104
Temperature rise
(ambient temperature at
70°C)
Max. 45°C
at max. switching current
Electrical
(at 20 cpm)
(at nominal (3 A 125 V AC) (at nominal (8 A 125 V AC)
operating
capacity)
105
operating
capacity)
105
operations)
(3 A 30 V DC)
(5 A 30 V DC)
Functional*5
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
98 m/s2 {10 G}, 10 to 55 Hz at
double amplitude of 1.6 mm
Shock
Coil (at 20°C 68°F)
Standard type
Destructive*6
Functional*7
resistance
Nominal operating power
Nominal operating power
400 mW
200 mW
High sensitivity type
Vibration
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2 mm
resistance
Remarks
Destructive
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section
*2 Detection current: 10mA
Conditions for operation, Ambient
–40°C to +70°C
–40°F to +158°F
transport and storage*8
(Not freezing and condens-
ing at low temperature)
temp.
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time
Humidity
5 to 85% R.H.
*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*6 Half-wave pulse of sine wave: 6ms
Unit weight
Approx. 7 g .25 oz
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
TYPICAL APPLICATIONS ORDERING INFORMATION
• Microwave oven (fan, inside lamp)
Ex. JZ
1a
F
S
9 V
TV
• Machineries which need electrical
noise resistance and surge resistance,
(Ex. hot-water heater)
Contact
Protective
arrangement construction
Coil voltage
(DC)
Type classification
Type classification
1a: 1 Form A F: Flux-resistant Nil: Standard
5, 6, 9, 12, Nil: UL/CSA/VDE
type
recognized type
(400 mW)
S: High sensitivity
(200 mW)
18, 24 V
TV: TV-5 rated type
Note: Standard packing Carton: 100 pcs. Case: 500 pcs.
UL/CSA, TV-5 (only for TV type) approved type is standard.