JWS-P-SERIES
Peak current / Single output 70 ~ 480W
Ⅵ Model name
JWS120P - 24
*24V output with cover
Nominal output voltage
Average output power
Series name
Ⅵ Features
ⅷ
marking (Low Voltage Directive)
ⅷ Applicable to peak output current, compact package
JWS70P
JWS120P
JWS240P
JWS480P
ⅷ
ⅷ
Universal Input (85 ~ 265VAC)
Power Factor & Harmonic Correction (Conform to EN61000-3-2)
ⅷ EMI (Built to meet EN55011-A, EN55022-A, VCCI-A, FCC-A)
ⅷ Remote ON/OFF control (JWS240P & JWS480P)
(Low Voltage Directive)
3 year warranty
Ⅵ Specifications
1. Input voltage range 85 ~ 265VAC ( 47 ~ 63Hz) Universal input
2. Power Factor
3. Cooling
0.99 (typ) at 100VAC Average load, 0.92 (typ) at 200VAC Average load
JWS70P, JWS120P: Convection cooling, JWS240P, JWS480P: Forced air by built-in blower
4. Operating
Temperature
–10 ~ +60°C (–10 ~ +50°C: 100%, +60°C: 60%)
5. Withstand Voltage
Input to output: 3kVAC (20mA), Input to FG: 2kVAC (20mA), Output to FG: 500VAC (100mA) for 1 min.
Built to meet EN55011-A, EN55022-A, FCC class A, VCC I class A
6. Conducted
emission noise
7. Radiated emission Built to meet EN55011-A, EN55022-A, FCC class A, VCC I class A
noise
8. PFHC
Built to meet EN61000-3-2
Approved by UL1950
9. Safety standard
10. Functions
, CSA950
, EN60950
, VDE0160
and UL508
(optional, Note)
OVP, OCP, Thermal protection, JWS240P, JWS480P: Remote ON/OFF control
Note: JWS150P 24V output with cover model - UL508 approval is expencted to be confirmed in August 2002
Ⅵ Line-up
Output
Voltage
24V
48V
24V
48V
24V
36V
48V
Average Output
Current
3.0A
Average Output
Power
72W
Peak output
Current (*1)
6.0A
3.0A
10.0A
5.0A
20.0A
13.3A
10.0A
Peak output
Power (*1)
144W
144W
240W
240W
480W
478.8W
480W
UL
CSA
EN
Model
JWS70P-24
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
JWS70P
JWS120P
JWS240P
JWS70P-48
JWS120P-24
JWS120P-48
JWS240P-24
JWS240P-36
JWS240P-48
JWS480P-24
JWS480P-48
1.5A
5.0A
2.5A
10.0A
6.65A
5.0A
20.0A
10.0A
72W
120W
120W
240W
239.4W
240W
480W
24V
48V
40.0A
20.0A
960W
960W
JWS480P
480W
⅜ : Safety standard approved
<
(*1) Operating time at peak output is less than 10 seconds. (Duty 0.5)
=
Ⅵ Outline drawing
JWS70P
ⅷRecommended Noise Filter
MAW-1202-22
G O !!
P134
G
O !!
ⅷRecommended Power Supply Fixture
P198
(Unit: mm)
29