NEMIC-LAMBDA
JWS 150
SPECIFICATIONS
A160-01-01A
JWS150
-3
JWS150
JWS150
-12
12
13
156
77
JWS150
-15
15
10
150
78
JWS150
-24
24
6.5
156
80
JWS150
-48
48
3.3
158.4
80
MODEL
-5
5
30
150
75
ITEMS
3.3
30
99
67
1 Nominal Output Voltage
2 Maximum Output Current
3 Maximum Output Power
4 Efficiency (Typ)
V
A
W
(*1) %
85 ~ 265VAC (47 ~ 63Hz) or 120 ~ 330VDC
2.0/1.0
5 Input Voltage Range
6 Input Current (100/200VAC)(Typ) (*1) A
(*2) -
1.5/0.75
25A at 100VAC, 50A at 200VAC, Ta=25°C, Cold Start
Built to meet EN61000-3-2
7 Inrush Current(Typ)
8 PFHC
-
-
0.99/0.95
9 Power Factor (100/200VAC)(Typ) (*1) -
2.85~3.63 4.5~5.5
10.8~13.2 13.5~16.5 21.6~26.4 43.2~52.8
10 Output Voltage Range
V
120
160
20
120
160
20
150
180
48
150
180
60
150
180
96
200
240
192
240
11 Maximum Ripple & Noise 0 ~ +60°C mV
(*3) -10 ~ 0°C mV
12 Maximum Line Regulation
13 Maximum Load Regulation
14 Temperature Coefficient
15 Over Current Protection
16 Over Voltage Protection
17 Hold-up Time (Typ)
18 Leakage Current
19 Remote Sensing
20 Parallel Operation
21 Series Operation
22 Operating Temperature
23 Operating Humidity
24 Storage Temperature
25 Storage Humidity
26 Cooling
27 Withstand Voltage
(*4) mV
(*5) mV
-
(*6) A
(*7) V
40
40
96
120
150
Less than 0.02%/°C
13.65 ~ 10.5 ~
31.5 ~
31.5 ~
6.82 ~
3.46 ~
3.79~4.95 5.75~6.75 13.8~16.2 17.3~20.3 27.6~32.4 55.2~64.8
20ms
0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
Possible
(*8)
(*9)
-
-
-
-
-
-
-
-
-
-
-
-
Possible
-10 ~+60°C ( -10 ~+50°C:100%, +60°C:60%)
30 ~ 90%RH (No dewdrop)
(*10)
-30 ~ +85°C
10 ~ 95%RH (No dewdrop)
Convection Cooling
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
More than 100MW at 25°C and 70%RH Output - FG ... 500VDC
At no operating, 10 ~ 55Hz (Sweep for 1min)
28 Isolation Resistance
29 Vibration
-
-
19.6m/s2 Constant, X,Y,Z 1hour each.
Less than 196.1m/s2
30 Shock (In package)
31 Safety
-
-
Approved by UL1950, CSA950, EN60950,VDE0160.
Built to meet DENTORI.
(*11)
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
850
32 Conducted Emission
33 Radiated Emission
34 Weight(Typ.)
-
-
g
65 x 92 x 198 ( Refer to Outline Drawing )
35 Size (W x H x D)
mm
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
input voltage range will be 100 ~ 240VAC(50/60Hz).
*3. Measure with EIAJ RC-9131 probe, Bandwise of scope :100MHz.
*4. 85 ~ 265VAC , constant load.
*5. No load-Full load, constant input voltage.
*6. Constant current limit with automatic recovery.
*7. OVP circuit will shut down output, manual reset (Line recycle).
*8. At 100/200VAC nominal output voltage and maximum output current.
*9. Measured by the each measuring method of UL,CSA,EN and DENTORI(at 60Hz).
*10. Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A160-01-02_).