Modified Sine Wave DC-AC Inverter with MPPT Solar Charger
ISI-500 series
Features :
Power ON-OFF switch
Protections: Bat. low alarm / Bat. low shutdown / Over temp.
/ Output short / Input polarity reverse / Over load
High frequecny design
Output voltage regulation : 10%
High surge power up to 1000W
Output wavform : Modified sine wave
Modified models available: 110/115/120VAC or 220/220/240VAC
Cooling fan ON-OFF control
Built-in MPPT solar charger
Built-in battery low relay contact
LED indicator for operation status
2 years warranty
SPECIFICATION
MODEL
ISI-500-112
Note.2 350W
ISI-500-124
ISI-500-148
ISI-500-212
ISI-500-224
ISI-500-248
RATED POWER
500W
500W
350W
700W
500W
500W
SURGE POWER (Typ.)
WAVEFORM
700W
1000W
1000W
1000W
1000W
Modified sine wave
110V
OUTPUT
AC VOLTAGE
230V
FREQUENCY
60Hz 0.5Hz
10%
50Hz 0.5Hz
AC REGULATION
LED INDICATOR
BAT. VOLTAGE
Green: Inverter OK, Green (flashing): Inverter OK and charging, Red: abnormal
24V
48V
24V
48V
12V
Note.3 10.5 ~ 15VDC
35A
12V
VOLTAGE RANGE
DC CURRENT (Typ.)
21 ~ 30VDC
25A
42 ~ 60VDC
12.5A
10.5 ~ 15VDC
35A
21 ~ 30VDC
25A
42 ~ 60VDC
12.5A
0.8A
0.4A
0.2A
INPUT
NO LOAD CURRENT DRAW 0.8A
OFF MODE CURRENT DRAW 1mA
0.4A
0.2A
EFFICIENCY (Typ.)
BATTERY TYPE
Note.1 85%
87%
87%
86%
88%
88%
Open & sealed Lead Acid
35 ~ 80V
15A
70 ~ 160V
7.5A
35 ~ 80V
15A
70 ~ 160V
7.5A
VOLTAGE RANGE
20 ~ 40V
20 ~ 40V
15A
SOLAR
PANEL
INPUT
MAX. SHORT CIRCUIT CURRENT 15A
RATED CHARGE POWER (Typ.) 350W
500W
30A
500W
15A
350W
40A
500W
30A
500W
15A
FUSE
40A
BATTERY
INPUT
PROTECTION
11V
22V
44V
11V
22V
BAT. LOW ALARM
Note.3
44V
10.5V
21V
42V
10.5V
21V
42V
BAT. LOW SHUTDOWN Note.3
REVERSE POLARITY
By internal fuse
55
10
65
10
55
10
50
10
70
10
50
10
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH9 detect power transistor
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover ; >105% load @ 60 sec.
Open : Battery low ; Short : Battery ok
OUTPUT
PROTECTION
OUTPUT SHORT
OVER LOAD
FUNCTION BAT. LOW RELAY CONTACT
WORKING TEMP.
-20 ~ +40 @ 100% load ; 60 @ 50% load
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
WORKING HUMIDITY
ENVIRONMENT
STORAGE TEMP., HUMIDITY
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
EN60950-1
None
LVD
WITHSTAND VOLTAGE
Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
EMC
Bat. I/P-AC O/P, Bat. I/P-FG, AC O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE
Compliance to EN61000-4-2,3,8
EMC EMISSION
EMS IMMUNITY
MTBF
Compliance to FCC class A
None
81.1K hrs min. MIL-HDBK-217F (25oC)
205*158*67mm (L*W*H)
1.92Kg; 6pcs/12.5Kg/1.55CUFT
OTHERS
NOTE
DIMENSION
PACKING
1.Efficiency is tested by 350W, linear load at 13V, 26V, 52V input voltage.
2.Output derating capacity referenced by curve 1.
3.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.
File Name:ISI-500-SPEC 2011-05-31