IMP
OUTPUT MODULE VOLTAGE/CURRENT* (CONTINUED)
Parallel Codes
Ordering Notes
iMP4
available slots
1. The cases and modules of both MP and iMP series can be inter-
changed to allow more flexibility. If intelligent modules are used
with non-intelligent cases, a numeric code “4” is placed at the end
of the module code (ex. 4LL0 becomes 4LL4).
iMP8
available slots
iMP1
available slots
2. USB to I2C module order code 73-769-001
7
6
5
4
3
2
1
0 = no parallel
1 = 1 & 2
2 = 2 & 3
3 = 3 & 4
4 = 4 & 5
5 = 3 & 4 & 5
6 = 5 & 6
7 = 4 & 5 & 6
8 = 6 & 7
9 = 3 & 4, 6 & 7
A = 1 & 2, 3 & 4, 5 & 6
C = 2 & 3, 4 & 5
E = 3 & 4, 5 & 6
F = 2 & 3, 4 & 5, 6 & 7
ORDERING INFORMATION
Case Size
Module/Voltage/Option Codes
First - Module Code
Case Option Codes
Software Code
Hardware Code
Second - Voltage Code
Third - Option Code
iMP1*
-
3L0 - 2E2 - 1Q1 - 4LL0
-
00
-
A
-
###
Software code
used for
configuration
change. “A” is
standard
Factory assembled
for hardware of
firmware mods.
Case Size (mm)
4 = 2.5” x 5” x 10”; 750 W - 1158 W,
Module Codes
Module/voltage/option codes
Module codes:
(None) = 36 W triple O/P (1 slot)
1 = 210 W single O/P (1 slot)
2 = 360 W single O/P (2 slot)
3 = 750 W single O/P (3 slot)
4 = 144 W dual O/P (1 slot)
5 = 1500 W single O/P (4 slot)
6 - 9 = future
Voltage Codes:
See Output Module Voltage/
Current table above
Option Codes:
0 = Standard
Case Option Codes
First digit
5 Slots
(63.5 x 127 x 254 mm)
8 = 2.5” x 7” x 10”; 1000 W - 1200 W,
6 Slots (63.5 x 177.8 x 254 mm)
1 = 2.5” x 8” x 11”; 1200 W - 1500 W,
7 Slots (63.5 x 203.2 x 279.4 mm)
0 - 9, A - Z parallel code
(See Parallel Codes table
above)
Second digit
0 = No options
1 = Reverse air
3 = Global enable
4 = Fan idle with inhibit
5 = Opt 1 + Opt 3
6 = Opt 1 + Opt 4
7 = Opt 3 + Opt 4
8 = Opt 1 +3 +4
* Note: Add “E” after iMP4 to denote IEC
input option.
e.g. iMP4E (Not available on iMP8 or iMP1)
1 = Module enable
2 = Constant current
3 = 1 & 2 combined
4 = Set for use in standard
(non-intelligent case)
5 = Shutdown mode for 1500 W
6 = 1 & 5 combined
9 = RS485 73-544-002
A = RS485 73-544-002 +
Reverse air
C = Opt 3 + Opt 9
D = CAN BUS 73-544-003
E = Opt 3 + Opt D
F = RS485 - MODBUS
73-544-005
7 - 9 = future
6