IMP  
ELECTRICAL SPECIFICATIONS (CONTINUED)  
Output  
Adjustment range*  
10% minimum all outputs (manual)  
(full module adjustment range using I2C)  
Factory set point accuracy  
I2C output program accuracy  
Margining  
1%  
5%  
4 - 6% nominal analog (single output module only)  
Overall regulation  
Ripple  
0.4% or 20 mV max. (1500 W modules 1% max.) (36 W modules 4% maximum)  
RMS: 0.1% or 10 mV, whichever is greater  
Pk-Pk: 1.0% or 50 mV, whichever is greater  
Bandwidth limited to 20 MHz  
Dynamic response  
Recovery time  
< 2% or 100 mV, with 25% load step  
To within 1% in < 300 µsec  
Overcurrent protection**  
Configurable through I2C (calibration required). Single output module and main output of the dual output module  
105 - 120% of rated output current. Aux output of dual output module 105 - 140% of rated output current  
Short-circuit protection  
Overvoltage protection*  
Protected for continuous short-circuit.  
Recovery is automatic upon removal of short  
Configurable through I2C  
Single output module: 2 to 5.5 V 122 to 134%; 6 to 60 V 110 to 120%  
Dual output module: 2 to 6 V 122 to 134%; 8 to 28 V 110 to 120%  
Triple output module: 110 - 120% of highest voltage rating  
Thermal protection*  
(OTP and OTW)  
Configurable through I2C  
All outputs disabled when internal temp exceeds safe operating range. > 5 ms warning (AC OK signal) before  
shutdown  
Remote sense  
Up to 0.5 V total drop (not available on triple output module)  
Current share to within 2% of total rated current  
5% of nominal. Configurable through I2C  
Not required  
Single wire parallel  
DC OK*  
Minimum load  
Housekeeping bias voltage  
Module inhibit*  
5 Vdc @ 1.0 A max. present whenever AC input is applied (Optional 2.0 A available)  
Configured and controlled through I2C  
Switching frequency  
Output/Output isolation  
External sync  
250k Hz accepts external sync signal  
> 1 Megohm, 500 V  
TTL clock input signal used to adjust switching frequency. Frequency 500 kHz  
20%; Duty cycle 40 - 55%  
*
Can be controlled via I2C  
** Controlled via I2C but requires load calibration  
INTERNAL PART NUMBER REFERENCE TABLE  
Part #  
Description  
iMP8 Case  
iMP1 Case  
iMP4 Case  
Case Code  
iMP8  
73-580-0001i  
73-690-0001i  
73-540-0001i  
iMP1  
iMP4  
advancedenergy.com  
3

与IMP1-2E0-2E0-00-A相关器件

型号 品牌 描述 获取价格 数据表
IMP1-2F0-2F0-00-A ARTESYN IMP CONFIGURABLE POWER SUPPLY

获取价格

IMP1-2F0-2Q0-2Q0-4NN-40-A ARTESYN IMP CONFIGURABLE POWER SUPPLY

获取价格

IMP1-2L0-1E0-1U0-1U0-4IC0-4NN0-00-A ARTESYN IMP CONFIGURABLE POWER SUPPLY

获取价格

IMP1-2L0-2Q0-2U0-00-A ARTESYN IMP CONFIGURABLE POWER SUPPLY

获取价格

IMP1-2M0-2M0-1D0-1Q0-4EE0-00-A ARTESYN IMP CONFIGURABLE POWER SUPPLY

获取价格

IMP1-2N0-2N0-1E0-1E0-4LL-01-A ARTESYN IMP CONFIGURABLE POWER SUPPLY

获取价格