60W Single Output Switching Power Supply
HLG-60H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet location or outdoor application
5 years warranty
110
F
M
M
SELV
IP65 IP67
HLG-60H-12
A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
D : (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
HLG-60H-15
HLG-60H-20
HLG-60H-24
HLG-60H-30
HLG-60H-36
HLG-60H-42
HLG-60H-48
HLG-60H-54
36V
42V
DC VOLTAGE
15V
20V
24V
30V
48V
54V
21.6 ~ 36V
1.7A
25.2 ~ 42V
1.45A
CONSTANT CURRENT REGION Note.4 9 ~ 15V
12 ~ 20V
3A
14.4 ~ 24V
2.5A
18 ~ 30V
2A
28.8 ~ 48V
1.3A
32.4 ~ 54V
1.15A
RATED CURRENT
RATED POWER
4A
61.2W
60.9W
60W
60W
60W
60W
62.4W
62.1W
200mVp-p
33 ~ 40V
300mVp-p
40 ~ 46V
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE Note.6 13.5 ~ 17V
150mVp-p
17 ~ 22V
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
300mVp-p
44 ~ 53V
300mVp-p
49 ~ 58V
OUTPUT
Can be adjusted by internal potential meter or through output cable
CURRENT ADJ. RANGE
2.4 ~ 4A
VOLTAGE TOLERANCE Note.3 2.0%
1 ~ 1.7A
1.0%
0.87 ~ 1.45A
1.0%
1.8 ~ 3A
1.0%
1.5 ~ 2.5A
1.0%
1.2 ~ 2A
1.0%
0.78 ~ 1.3A
1.0%
0.69 ~ 1.15A
1.0%
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5%
1.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
Note.8 1500ms, 80ms / 115VAC at full load
1000ms, 80ms / 230VAC at full load
16ms/115VAC at full load
127 ~ 431VDC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
16ms/230VAC
Note.5 90 ~ 305VAC
47 ~ 63Hz
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT
90%
91%
91%
91%
91%
88%
91%
90%
0.64A / 115VAC
0.32A / 230VAC
0.3A / 277VAC
COLD START 70A/230VAC
<0.75mA / 277VAC
95 ~ 108%
OVER CURRENT
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
48 ~ 58V
18 ~ 24V
Protection type : Shut down o/p voltage, re-power on to recover
95 10 (RTH2)
23 ~ 30V
28 ~ 35V
35 ~ 43V
41 ~ 49V
54 ~ 63V
59 ~ 66V
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0 ~ 60
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.7
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
UL8750, EN61347-1, EN61347-2-13 independent ; IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
SAFETY &
EMC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, heavy industry level (surge 4KV), criteria A
EMC IMMUNITY
MTBF
338Khrs min. MIL-HDBK-217F (25
171*61.5*36.8mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.73Kg; 20pcs/15.6Kg/0.8CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:HLG-60H-SPEC 2011-05-30