80W Single Output Switching Power Supply
HLG-80H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
"UL8750 listed" safety approved for HLG-80H- BL
Class 2 power unit
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.10)
110
F
M
M
SELV
IP65 IP67
(for HLG-80H-48/54 only)
(except for HLG-80H-48/54)
(except for HLG-80H-48/54BL)
(for HLG-80H-48/54BL only) (for HLG-80H-12~42BL only)
(except for BL type)
HLG-80H-12
A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
BL (option) : Contact MEAN WELL for details.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
HLG-80H-12
HLG-80H-15
HLG-80H-20
HLG-80H-24
HLG-80H-30
HLG-80H-36
HLG-80H-42
HLG-80H-48
HLG-80H-54
36V
42V
DC VOLTAGE
12V
15V
20V
24V
30V
48V
54V
21.6 ~ 36V
2.3A
25.2 ~ 42V
1.95A
CONSTANT CURRENT REGION Note.4 7.2 ~12V
9 ~ 15V
5A
12 ~ 20V
4A
14.4 ~ 24V 18 ~ 30V
28.8 ~ 48V 32.4 ~ 54V
RATED CURRENT
RATED POWER
5A
3.4A
2.7A
1.7A
1.5A
82.8W
81.9W
60W
75W
80W
81.6W
81W
81.6W
81W
200mVp-p
33 ~ 40V
200mVp-p
38 ~ 46V
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
43 ~ 53V
200mVp-p
49 ~ 58V
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V 13.5 ~ 17V 17 ~ 22V
OUTPUT
Can be adjusted by internal potentiometer or through output cable
CURRENT ADJ. RANGE
3 ~ 5A
VOLTAGE TOLERANCE Note.3 2.5%
1.38 ~ 2.3A 1.17 ~ 1.95A
1.02 ~ 1.7A 0.9 ~ 1.5A
3 ~ 5A
2.0%
0.5%
1.5%
2.4 ~ 4A
1.0%
2.04 ~ 3.4A 1.62 ~ 2.7A
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5%
2.0%
0.5%
1.0%
Note.8 2000ms, 80ms / 115VAC at full load
1000ms, 80ms / 230VAC at full load ; B type 2000ms, 200ms at 95% load 230VAC / 115VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
16ms at full load 230VAC /115VAC
Note.5 90 ~ 305VAC
127 ~ 431VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
47 ~ 63Hz
PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT
88%
90%
91%
91%
91%
91%
89%
91%
90.5%
0.85A / 115VAC
0.425A / 230VAC
0.4A / 277VAC
COLD START 70A/230VAC
<0.75mA / 277VAC
95 ~ 108%
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
35 ~ 43V
Protection type : Shut down o/p voltage, re-power on to recover
85 10 (RTH2)
41 ~ 49V
48 ~ 58V
54 ~ 63V
59 ~ 68V
14 ~ 17V
18 ~ 24V
23 ~ 30V
28 ~ 35V
PROTECTION
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
-40 ~ +80 , 10 ~ 95% RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
0.03%/ (0 ~ 60
)
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08(except for HLG-80H-48/54V & HLG-80H-48/54BL), UL8750 listed for HLG-80H- BL
EN61347-1, EN61347-2-13 independent, J61347-1, J61347-2-13, IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
SAFETY STANDARDS Note.7
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
EMC IMMUNITY
MTBF
357.8Khrs min. MIL-HDBK-217F (25
195.6*61.5*38.8mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.84Kg; 16pcs/14.4Kg/0.54CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.