SPECIFICATION
MODEL
HLG-120H-C350
HLG-120H-C500
HLG-120H-C700
HLG-120H-C1050
HLG-120H-C1400
RATED CURRENT
CURRENT ACCURACY
CONSTANT CURRENT REGION
RATED POWER
350mA
±5.0%
500mA
700mA
1050mA
1400mA
Note.6
215 ~ 430V
150.5W
±5%
150V ~ 300V
150W
107V ~ 215V
150.5W
74V ~ 148V
155.4W
54V ~ 108V
151.2W
RIPPLE CURRENT
RIPPLE & NOISE
OUTPUT
1Vp-p
1Vp-p
0.5Vp-p
0.5Vp-p
0.5Vp-p
Can be adjusted by internal potentiometer (A type)
CURRENT ADJ. RANGE
175 ~ 350mA
250 ~ 500mA
350 ~ 700mA
525 ~ 1050mA
700 ~ 1400mA
LINE REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
±1%
±1%
±1%
±1%
±1%
2000ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load
16ms at full load 230VAC / 115VAC
Note.2
VOLTAGE RANGE
90 ~ 305VAC
47 ~ 63Hz
127VDC ~ 431VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
93.5%
INPUT
A / 115VAC
A / 230VAC
/ 277VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
μ
peak
s measured at 50% I ) at 230VAC
width
COLD START 70A(t
=
<0.75mA / 277VAC
Hiccup mode, recovers automatically after fault condition is removed
475 ~ 495V 335 ~ 355V 240 ~ 260V
SHORT CIRCUIT
OVER VOLTAGE
165 ~ 175V
120 ~ 130V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
85℃±10℃ (RTH2)
PROTECTION
ENVIRONMENT
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING TEMP.
10 ~ 95% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
Note.3
SAFETY STANDARDS
WITHSTAND VOLTAGE
UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13, EN62384 independent, IP65 or IP67 approved
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
SAFETY &
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55015, EN61000-3-2 Class C (≧50% load) ; EN61000-3-3
, heavy industry level (surge L,N-FG: 4KV), criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547
K hrs min. MIL-HDBK-217F (25℃)
220*68*38.8mm (L*W*H)
EMC IMMUNITY
MTBF
OTHERS
NOTE
DIMENSION
PACKING
Kg; 12pcs/ Kg/0.8CUFT
℃
File Name:HLG-120H-C-SPEC 2013-02-08