Compact Laser Displacement Sensor
1023
HL-G1 SERIES
■General terms and conditions............. F-3
■Selection guide........................... P.1021~
■About laser beam........................ P.1593~
FIBER
SENSORS
Related Information
■
Glossary of terms / General precautions ..... P.1587 / P.1595
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Conforming to
FDA regulations
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
This product is classified
as a Class 2 (specular
reflection type: Class 1)
Laser Product in IEC / JIS
standards and in FDA*
regulations. Do not look
at the laser beam directly
or through optical system
such as a lens.
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
*
This product complies with 21 CFR 1040.10
and 1040.11 Laser Notice No. 50, dated
June 24, 2007, issued by CDRH (Center for
Devices and Radiological Health) under the
FDA (Food and Drug Administration).
MEASUREMENT
SENSORS
panasonic.net/id/pidsx/global
STATIC
CONTROL
DEVICES
LASER
MARKERS
Introducing the new standard in CMOS laser displacement sensors
PLC
This single instrument delivers both high-precision measurement and computer-driven data analysis
HUMAN MACHINE
INTERFACES
A total of 8 models accommodate a
High resolution of
ENERGY
MANAGEMENT
SOLUTIONS
variety of applications
0.5 μm 0.020 mil
Thanks to high-precision
measurement at a resolution of
0.5 μm 0.020 mil and an LED digital
display that provides exceptional
ease of use, the HL-G1 series will
see use in a variety of applications on
production lines worldwide.
FA COMPONENTS
Diffuse reflection type
Specular reflection type
MACHINE VISION
SYSTEMS
HL-G103□
HL-G103A□
Measurement range: 30 ±4 mm
Measurement range: 26.3 ±2 mm
1.035 ±0.079 in
UV CURING
SYSTEMS
1.181 ±0.157 in
Resolution:
Linearity:
Beam diameter:
0.5 μm 0.020 mil
±0.1 % F.S.
0.1 × 0.1 mm
0.004 × 0.004 in
Resolution:
Linearity:
Beam diameter:
0.5 μm 0.020 mil
±0.2 % F.S.
0.1 × 0.1 mm
0.004 × 0.004 in
Diffuse reflection type
Specular reflection type
Selection
Guide
Laser
Displacement
Magnetic
Displacement
Contact
Displacement
Collimated
Beam Sensors
Metal-sheet
Double-feed Detection
Digital Panel
Controller
HL-G105□
HL-G105A□
Quick
Measurement range: 50 ±10mm
Measurement range: 47.3 ±5 mm
1.862 ±0.197 in
1.969 ±0.394 in
1.5 μm 0.059 mil
±0.1 % F.S.
Setup is fast and efficient by using the
built-in digital display to set measurement
parameters such as sampling cycle and
output options.
Resolution:
Linearity:
Resolution:
Linearity:
Beam diameter:
1.5 μm 0.059 mil
±0.2 % F.S.
0.1 × 0.1 mm
0.004 × 0.004 in
Beam diameter:
0.5 × 1.0 mm
0.020 × 0.039 in
Diffuse reflection type
Specular reflection type
HL-G108□
HL-G108A□
Measurement range: 85 ±20 mm
Measurement range: 82.9 ±10 mm
3.264 ±0.394 in
3.346 ±0.787 in
2.5 μm 0.098 mil
±0.1 % F.S.
Compact
Resolution:
Linearity:
Resolution:
Linearity:
Beam diameter:
2.5 μm 0.098 mil
±0.2 % F.S.
0.2 × 0.2 mm
0.008 × 0.008 in
Other Products
Beam diameter:
0.75 ×1.25 mm
0.030×0.049 in
The HL-G1 series features a compact
design despite its built-in controller
and digital readout. Thanks to our
miniaturization technology, it can easily
be installed on robot arms and in confined
spaces.
HL-G1
HL-C2
HL-D3
Diffuse reflection type
HL-G112□
Measurement range: 120 ±60 mm
4.724 ±2.362 in
Resolution:
Linearity:
8 μm 0.315 mil
±0.1 % F.S.
Beam diameter:
1.0 × 1.5 mm
0.039 × 0.059 in
Friendly
Diffuse reflection type
The HL-G1 series now features a user-
friendly interface that offers improved
ease of use when operating via
HL-G125□
Measurement range: 250 ±150 mm
9.843 ±5.906 in
Resolution:
Linearity:
20 μm 0.787 mil
±0.3 % F.S.
Beam diameter:
1.75 × 3.5 mm
0.069 × 0.138 in
computer software or HMI unit for more
sophisticated operation and analysis.