150W Single Output Switching Power Supply
HLG-150H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 94%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.9)
110
F
M
M
SELV
IP65 IP67
HLG-150H-12
A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
HLG-150H-36
HLG-150H-42
MODEL
HLG-150H-12
HLG-150H-15
HLG-150H-20
HLG-150H-24
HLG-150H-30
HLG-150H-48
HLG-150H-54
36V
42V
DC VOLTAGE
12V
15V
20V
24V
30V
48V
54V
4.2A
3.6A
RATED CURRENT
RATED POWER
12.5A
150W
10A
7.5A
6.3A
5A
3.2A
2.8A
151.2W
200mVp-p
33 ~ 40V
151.2W
200mVp-p
38 ~ 46V
150W
150mVp-p
150W
150mVp-p
151.2W
150mVp-p
22 ~ 27V
150W
200mVp-p
27 ~ 33V
153.6W
200mVp-p
43 ~ 53V
151.2W
200mVp-p
49 ~ 58V
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE Note.5 10.8 ~ 13.5V 13.5 ~ 17V 17 ~ 22V
Can be adjusted by internal potentiometer or through output cable
OUTPUT
CURRENT ADJ. RANGE
2.5 ~ 4.2A
1.0%
2.16 ~ 3.6A
1.0%
7.5 ~ 12.5A 6 ~ 10A
4.5 ~ 7.5A
1.0%
3.8 ~ 6.3A
1.0%
3 ~ 5A
1.0%
0.5%
0.5%
1.92 ~ 3.2A 1.68 ~ 2.8A
VOLTAGE TOLERANCE Note.3 2.5%
2.0%
0.5%
1.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5%
2.0%
0.5%
0.5%
0.5%
0.5%
1.0%
0.5%
Note.7 2500ms, 80ms at full load 230VAC / 115VAC ; B type 2500ms, 200ms at 95% load 230VAC / 115VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
16ms at full load 230VAC / 115VAC
Note.4 90 ~ 305VAC
127 ~ 431VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT
91.5%
93%
93.5%
94%
94%
94%
92%
93.5%
93%
1.7A / 115VAC
0.75A / 230VAC
0.7A / 277VAC
COLD START 75A/230VAC
<0.75mA / 277VAC
95 ~ 108%
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
34 ~ 38V
41 ~ 46V
47 ~ 53V
54 ~ 60V
59 ~ 65V
14 ~ 17V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
100 10 (RTH2)
18 ~ 21V
23 ~ 27V
28 ~ 34V
PROTECTION
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-40 ~ +70 (Refer to "Derating Curve")
WORKING TEMP.
20 ~ 95% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ;
design refer to UL60950-1, TUV EN60950-1
SAFETY STANDARDS Note.6
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
EMC IMMUNITY
MTBF
192.2
Khrs min. MIL-HDBK-217F (25
)
228*68*38.8mm
OTHERS
NOTE
DIMENSION
PACKING
1.15Kg; 12pcs/14.8Kg/0.74CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Type A and type C only.
6. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Refer to warranty statement.