HER201 THRU HER208
2.0 AMP HIGH EFFICIENCY RECTIFIERS
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
2.0 Amperes
FEATURES
* Low forward voltage drop
* High current capability
* High reliability
DO-15
.140(3.6)
.104(2.6)
DIA.
* High surge current capability
* High speed switching
1.0(25.4)
MIN.
MECHANICAL DATA
* Case: Molded plastic
.300(7.6)
.230(5.8)
* Epoxy: UL 94V-0 rate flame retardant
* Lead: Axial leads, solderable per MIL-STD-202,
method 208 guranteed
* Polarity: Color band denotes cathode end
* Mounting position: Any
1.0(25.4)
MIN.
.034(.9)
*
Weight: 0.40 grams
.028(.7)
DIA.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
HER201 HER202 HER203 HER204 HER205 HER206 HER207 HER208 UNITS
50
35
50
100
70
200
140
200
300
210
300
400
280
400
600
420
600
800 1000
560 700
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
V
V
V
100
800 1000
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Ta=50 C
2.0
A
A
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Instantaneous Forward Voltage at 2.0A
Maximum DC Reverse Current
60
1.0
1.3
5.0
1.85
70
V
µA
Ta=25 C
at Rated DC Blocking Voltage
Ta=100 C
150
µA
nS
Maximum Reverse Recovery Time (Note 1)
Typical Junction Capacitance (Note 2)
Operating and Storage Temperature Range TJ, TSTG
50
30
pF
C
-65 +150
NOTES:
1. Reverse Recovery Time test condition: IF=0.5A, IR=1.0A, IRR=0.25A
2. Measured at 1MHz and applied reverse voltage of 4.0V D.C.