HER101 THRU HER107
VOLTAGE 50V ~ 1000V
Elektronische Bauelemente
1.0 AMP High Efficiency Rectifier
A suffix of "-C" indicates halogen-free & RoHS Compliant
DO-41
FEATURES
.107(2.7)
.080(2.0)
DIA.
.
.
.
.
.
.
RoHS Compliant Product
1.0(25.4)
MIN.
Low Forward Voltage Drop
High Current Capability
High Reliability
.205(5.2)
.166(4.2)
High Surge Current Capability
High Speed Switching
1.0(25.4)
MIN.
.034(.9)
.028(.7)
DIA.
MECHANICAL DATA
.
.
.
Case: Molded Plastic
Dimensions in inches and (millimeters)
Epoxy: UL 94V-0 Rate Flame Retardant
Lead: Axial Lead, Solder Able per MIL-STD-202,
Method 208 Guaranteed
.
.
.
Polarity: Color Band Denotes Cathode End
Mounting Position: Any
Weight: 0.34 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Tamb = 25 °C unless otherwise specified
Single phase half-wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%)
Parameter
HER101 HER102 HER103 HER104 HER105 HER106 HER107 Units
Max. recurrent peak reverse voltage
Max. RMS voltage
50
35
50
100
70
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
V
V
V
Max. DC blocking voltage
100
1000
Max. avg. forward rectified current,
1.0
30
A
.375” (9.5mm) lead length at Ta = 55 °C
Peak forward surge current, 8.3 ms
single-half sine-wave superimposed on
rated load (JEDEC method)
A
Max. instantaneous forward voltage at 1.0A
1.0
1.3
5.0
100
1.7
V
Max. DC reverse current
Ta = 25 °C
Ta =100 °C
μA
at rated DC blocking voltage
Max. reverse recovery time (Note 1)
Typical junction capacitance (Note 2)
Operating temperature range TJ
Storage temperature range TSTG
50
20
75
15
ns
pF
°C
°C
-65~+150
-65~+150
Notes:
1. Reverse Recovery Time Test condition: IF = 0.5 A, IR = 1.0 A, IRR = 0.25 A
2. Measured at 1 MHz and applied reverse voltage of 4.0V D.C.
http://www.SeCoSGmbH.com/
Any changing of specification will not be informed individual
Page 1 of 2
01-Jun-2006 Rev. B