HED SERIES - DUAL OUTPUT, 30 WATT
DESCRIPTION
FEATURES
HED dual output DC/DC converters are fully isolated • 30W Dual Output
• Planar Magnetics
• Output Trim
• 1500V Isolation
converters featuring high efficiency topology. The
HED has fixed frequency design with excellent
transient response and predictable EMI performance.
The HED uses planar magnetics, and has open-frame
packaging, 1500 VDC isolation, and an MTBF of over
one million hours. HED’s have overcurrent and
overvoltage protection, as well as input undervoltage
lockout.
• OVP and Short Circuit
Protection
• High Efficiency Topology • 100°C Baseplate
Operation
• Open-Frame Design
TECHNICAL SPECIFICATIONS
Input
Voltage Range
24 VDC / 48 VDC Nominal
Reflected Ripple
18 - 36 / 34 - 75 VDC
25 mA
Input Reverse Voltage Protection
Input Transient Withstand
Inrush Current Limit
Shunt Diode
100V /100 ms
1A2/s
Efficiency vs. Load (48V Input)
Output
Setpoint Accuracy, Vout1 / Vout2
±1% / ±2%
1.0% / 2.0% Vout
1.0% / 5.0% Vout
10% Vout Rated
25% Iout
90
85
80
75
70
65
60
Line Regulation Vin Min. - Vin Max., Iout Rated, Vout1 / Vout2
Load Regulation Iout Min. - Iout Max., Vin Nom., Vout1 / Vout2
Minimum Output Current
Dynamic Regulation, Loadstep
HED030ZHH-A
Pk Deviation
Settling Time
Voltage Trim Range
Power Limit Threshold Range, % of Io Rated
4% Vout
500 µs
±10%
EFF. (36v)
EFF. (48v)
EFF. (75v)
110 - 140%
OVP Trip Range
OVP Type
115 - 140% Vout Nom.
Hiccup
10
20
30
40
50
60
70
80
90
100
OCP Type
Continuous
LOAD %
General
Turn-On Time
10 ms
Positive Logic
300 kHz
Remote Shutdown1
Switching Frequency
Isolation
Notes
Input - Output
1500 VDC
1050 VDC
500 VDC
0.03%/°C
†
MTBF predictions may vary slightly from model to model.
Input - Case
Output - Case
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Temperature Coefficient
Case Temperature
Operating Range
-40 To +100°C
-40 To +125°C
105 To 115°C
95%
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Storage Range
Thermal Shutdown Range
Humidity, Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
5 g, 10 - 55 Hz
MTBF (Bellcore TR-NWT-000332)
1.3 X 106 hrs
†
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
Safety
Weight (Approx.)
Consult Factory
1.4 oz