H
High CMR Isolation Amplifiers
Technical Data
HCPL-7800
HCPL-7800A
HCPL-7800B
applications, we recommend the
HCPL-7800 which exhibits a
part-to-part gain tolerance of
± 5%. For precision applications,
HP offers the HCPL-7800A and
HCPL-7800B, each with part-to-
part gain tolerances of ± 1%.
Features
• 15 kV/µs Common-Mode
Rejection at VCM = 1000 V*
• Compact, Auto-Insertable
Standard 8-pin DIP Package
• 4.6 µV/°C Offset Drift vs.
Temperature
• 0.9 mV Input Offset Voltage
• 85 kHz Bandwidth
• 0.1% Nonlinearity
• Worldwide Safety Approval:
UL 1577 (3750 V rms/1 min),
VDE 0884 and CSA
• Advanced Sigma-Delta(Σ∆)
A/D Converter Technology
• Fully Differential Circuit
Topology
• 1 µm CMOS IC Technology
• Switch-Mode Power Supply
Signal Isolation
• General Purpose Analog
Signal Isolation
• Transducer Isolation
Description
The HCPL-7800 high CMR
isolation amplifier provides a
unique combination of features
ideally suited for motor control
circuit designers. The product
provides the precision and
stability needed to accurately
monitor motor current in high-
noise motor control environ-
ments, providing for smoother
control (less “torque ripple”) in
various types of motor control
applications.
The HCPL-7800 utilizes sigma-
delta (Σ∆) analog-to-digital
converter technology, chopper
stabilized amplifiers, and a fully
differential circuit topology
fabricated using HP’s 1 µm
CMOS IC process. The part also
couples our high-efficiency, high-
speed AlGaAs LED to a high-
speed, noise-shielded detector
Functional Diagram
Applications
• Motor Phase Current
Sensing
• General Purpose Current
Sensing
• High-Voltage Power Source
Voltage Monitoring
I
I
DD2
DD1
This product paves the way for a
smaller, lighter, easier to produce,
high noise rejection, low cost
solution to motor current
sensing. The product can also be
used for general analog signal
isolation applications requiring
high accuracy, stability and
1
8
V
V
DD1
DD2
I
I
IN
O
7
6
2
3
V
V
V
IN+
+
-
+
-
OUT+
OUT-
V
IN-
*The terms common-mode rejection
(CMR) and isolation-mode rejection (IMR)
are used interchangeably throughout this
data sheet.
4
5
linearity under similarly severe
noise conditions. For general
GND1
GND2
CMR SHIELD
CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to
prevent damage and/or degradation which may be induced by ESD.
1-216
5965-3592E