Series HA60/HD60
25-125Amp • 600 Vac • AC Output
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
4000 Vrms
109 Ohm
8 pF
Ambient Operating Temperature Range
Ambient Storage Temperature Range
-40 to 80ºC
-40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
Screws and Saddle Clamps Furnished, Unmounted
AVAILABLE OPTIONS
E
24 VAC Input (18-36 Vac)
Example: HA6025E
1.10
(27.9)
MOUNTING
HOLE/SLOT
8-32 TERMINAL
(2 PLACES )
.45
(11.4)
0.17 (4.3) DIA.
-10
Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: HD6090-10
OUTPUT
2.30
(58.4)
1
2
1.87
(47.5)
F
Faston Terminals (Up to 50 Amp Models)
SOLID-STATE RELAY
1.70
(43.2)
--
+
4
3
INPUT
1.00
.78
BASE PLATE
.125 (3.2)
(25.4)
6-32 TERMINAL
(2 PLACES)
(19.8)
.90
(22.9)
1.80
(45.7)
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
1.10
FASTON TERMINAL
.250 X .032 (2 PLCS.)
(27.9)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
.87 REF.
(22.2)
.45
(11.4)
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
1
2
OUTPUT
2.30
(58.4)
1.87
(47.5)
1.70
(43.2)
INPUT
4
3
Crydom Heat Sinks offer excellent
thermal management and are per-
fectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
.78
1.00
BASE PLATE
.125 (3.2)
FASTON
(19.8)
(25.4)
TERMINAL
.187 X .032
(2 PLCS.)
.90
(22.9)
1.80
(45.7)
All dimensions are in inches (millimeters)
©1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
APPROVALS
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
UL E116950
CSA LR81689
VDE 10143 UG
FastFax Document No.159
SERIES HA/HD60.032698, PAGE 2 OF 3
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: vertrieb@crydom.com