S
e
r
i
es
HA/HD60
125
Featuring state-of-the-art Surface
25
-
Amp • 600 Vac - AC OUTPUT
• Zero Voltage and Random
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross, random
turn-on (phase controllable) and ver-
sions with either AC or DC input (coil)
control.
Turn-On Switching
• Panel Mount
• 1200V Blocking Capability
• 600Vac - the preferred
choice in Canada
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
AC CONTROL
DC CONTROL
HA6025
HD6025
HA6050
HD6050
HA6090
HD6090
HA60125
HD60125
MODEL NUMBERS
➀
OUTPUT SPECIFICATIONS
Nominal Line Voltage (±10%) [Vrms]
600
48-660
25
600
48-660
50
600
48-660
90
600
48-660
125
Operating Voltage Range (47-63 Hz) [Vrms]
Max. Load Current [Arms]
➀
Min. Load Current, [mArms]
40
40
40
150
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
1200
250
1.7
1200
625
1.7
1200
1,200
1.7
1200
1,750
1.7
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R
) [˚ C/W]
θJC
2
1.02
260
5
0.63
1,620
5
0.28
6,000
5
0.22
12,700
5
2
Maximum I t for Fusing, (8.3 msec.) [A sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➀
Max. Turn-On Time ➀
➀
500
500
500
500
1/2 Cycle (DC Input), 10.0 msec (AC Input)
1/2 Cycle (DC Input), 40.0 msec (AC Input)
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS ➀
DC CONTROL
AC CONTROL
AC CONTROL
( D P R E F I X )
( A P R E F I X ) ➀
( E S U F F I X )
Control Voltage Range
Max. Reverse Voltage
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
3-32 Vdc
-32 Vdc
90-280 Vrms (60Hz)
18-36 Vrms
---
---
3.0 Vdc
90 Vrms
18 Vrms
4.0 Vrms
9.0K Ohms
1.0 Vdc
10 Vrms
See Note ➀
2.0 mA➀
60K Ohms
2mA @ 120 Vrms, 4mA @ 240 Vrms 3mA @ 24 Vrms
© 2003 CRYDOM CORP, Specifications subject to change without notice.
G E N E R A L N O T E S
➀ All parameters at 25˚C unless otherwise specified.
➀ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➀ Heat sinking required, for derating curves see page 2.
➀ 24 Vac Input option, E suffix.
➀ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
➀ Input circuitry incorporates active current limiter.
➀ No internal snubber.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
FastFax Document No.159
SERIES HA/HD60.
Rev. 111303
PAGE 1 OF 3