12 kV
Features:
Kilovac H-14 Make & Break Load Switching
Double pole, double throw contacts
Vacuum dielectric for power switching low
current loads
30 Amps DC continuous current rating
Corona shield high voltage terminals available
Meets requirements of MIL-R-83725
Features:
Kilovac H-16 Make & Break Load Switching
12 kV rating; isolates 5 kV at 32 MHz
Vacuum dielectric for power switching low
current loads
Double pole, double throw contacts
Widely used as a transmit/receive switch
Meets requirements of MIL-R-83725
PRODUCT SPECIFICATIONS
COIL DATA
Nominal, Volts dc
12
26.5
115
Part Number
H-14
DPDT
2C
H-16
DPDT
2C
Units
Contact Arrangement ..........................................................
Contact Form ........................................................................
Test Voltage (dc or 60Hz) ...................................................
Rated Operating Voltage .....................................................
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Continuous Carry Current , Maximum
Pickup, Volts dc, Maximum
Drop-Out, Volts dc
8
16
80
.5 - 5 1 - 10 5 - 50
24 2000
120
15
15
kV Peak
kV Peak
Coil Resistance (Ohms ±10%)
Ratings listed are for 25°C, sea level conditions
12
10
8
12
10
8
PART NUMBER SELEC-
PART NUMBER SELEC-
ONIT
PART NUMBER SELECTION
Sample Part No.
Model
14
H
14 /12Vdc
5
5
Amps
16
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Coil Hi-Pot (V RMS, 60 Hz) ...........................................
Contact Capacitance ............................................................
Between Open Contacts .................................................
Open Contacts to Ground ..............................................
Contact Resistance, Maximum ...........................................
Operate Time, Maximum .....................................................
Release Time, Maximum .....................................................
Shock, 11 ms 1/2 Sine ........................................................
Vibration, 10 Gs Peak .........................................................
Operating Ambient Temperature Range ............................
Mechanical Life (Operations x 106) ....................................
Weight, Nominal ..................................................................
30
15
10
8
30
10
6
Coil Voltage
Blank = 26.5 Vdc
/12Vdc = 12 Vdc
/115Vdc = 115 Vdc
4
500
500
pF
1
1
2.5
2.5
ohms
ms
0.015
0.03
20
20
20
20
20
ms
Peak G's
20
Hz
oC
55-500
55-500
-55 to +125
0.5
-55 to +125
Cycles
oz.
1
8
6
CII Technologies
/ P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail info@kilovac.com / website www.ciitech.com