APPLICABLE STANDARD
OPERATING
TEMPERATURE RANGE
RATING
STORAGE
TEMPERATURE RANGE
-40 C TO +105 C (NOTE1)
-40 C TO +105 C
CURRENT
VOLTAGE
250 V AC
3
A
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
ACCORDING TO DRAWING.
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
×
×
×
×
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
INSULATION RESISTANCE
VOLTAGE PROOF
1A DC.
30 mΩ MAX .
30 mΩ MAX .
-
-
-
-
20 mV AC MAX, 0.1 mA(DC OR 1000Hz)
500 V DC
1000 MΩ MIN .
×
×
-
-
650 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
MECHANICAL OPERATION
30 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE: 60 m MAX .
② NO DAMAGE, CRACK AND LOOSENESS OF
-
×
-
-
PARTS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE: 60 m MAX .
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
VIBRATION
FREQUENCY 20 TO 200 Hz,
43.1 m/s2 AT 3 h FOR
DIRECTIONS.
-
-
×
-
-
-
3
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE: 60 m MAX .
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
SHOCK
FREQUENCY 20 TO 50 Hz,
66.6 m/s2 AT 1 h .
-
-
×
-
-
-
① DURING APPLYING,MATING COMPLETELY.
② AFTER APPLYING,NO DEFECT OF MATING
PARTS.
LOCK STRENGTH
APPLYING A PULL FORCE THE MATING
AXIALLY AT 29.4 N MAX.
×
×
-
-
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
(STEADY STATE)
① CONTACT RESISTANCE: 60 m MAX .
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
EXPOSED AT 60 C, 90 ~ 95 %, 500 h.
-
-
×
-
-
-
RAPID CHANGE OF
TEMPERATURE
① CONTACT RESISTANCE: 60 m MAX .
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
TEMPERATURE-40→5 TO 35→ 85→5 TO 35C
TIME 30 → → 30 → 5 min
UNDER 1000 CYCLES.
-
-
×
-
-
-
5
DRY HEAT
① CONTACT RESISTANCE: 60 m MAX .
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
EXPOSED AT 80C , 300 h.
EXPOSED AT -55C , 120 h.
-
×
-
-
COLD
① CONTACT RESISTANCE: 60 m MAX .
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
-
×
-
-
RESISTANCE TO SO2 GAS
EXPOSED IN 500 PPM FOR 8h.
CONTACT RESISTANCE: 60 m MAX .
-
-
-
-
-
NO DEFORMATION OF CASE OF EXCESSIVE
LOOSENESS OF THE TERMINALS.
RESISTANCE TO
SOLDERING HEAT
SOLDER TEMPERATURE, 260 C FOR
IMMERSION, DURATION, 10 s.
A NEW UNIFORM COATING OF SOLDER
SHALL COVER A MINIMUM OF 95 % OF
THE SURFACE BEING IMMERSED.
SOLDERABILITY
SOLDERED AT SOLDER TEMPERATURE,
230 C FOR IMMERSION DURATION, 3 s.
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
(NOTE1)
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
AR.SHIRAI
17.10.25
17.10.25
17.10.25
17.10.25
INCLUDE THE TEMPERATURE RISING BY CURRENT.
AR.SHIRAI
HS.OZAWA
YP.SHEN
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-166341-00-00
GT8E-8DS-2C
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL758-0027-1-00
FORM HD0011-2-1