APPLICABLE STANDARD
OPERATING
TEMPERATURE RANGE
RATING
STORAGE
TEMPERATURE RANGE
-40 C TO 105 C (NOTE1)
-40 C TO 105 C
1
A
VOLTAGE
50 V DC
CURRENT
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
STRUCTURE
EXAMINATION OF
APPEARANCE,
STRUCTURE AND
FINISHING
MEASUREMENT VIA VISUAL CHECK AND
MEASURING INSTRUMENT
BE CONSISTENT WITH DRAWING.
X
X
MARKING
VISUAL CONFIRMATION
X
X
ELECTRICAL CHARACTERISTICS
CONTACT RESISTANCE
CONTACT RESISTANCE-
MILLIVOLT METHOD
MEASURE AT 1A DC.
MEASURE AT 20 mV AC MAX,
0.1 mA(DC OR 1000Hz)
50 mΩ MAX
50 mΩ MAX
-
-
-
-
X
X
INSULATION RESISTANCE MEASURE AT 500 V DC
APPLY 125 V AC FOR 1 min.
VOLTAGE RESISTANCE
100 MΩ MIN.
NO FLASHOVER OR BREAKDOWN.
-
-
MECHANICAL CHARACTERISTICS
① CONTACT RESISTANCE: 100 m MAX.
MECHANICAL OPERATION 30 TIMES INSERTIONS AND EXTRACTIONS.
-
-
-
-
-
-
-
-
-
-
X
②
NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
① NO ELECTRICAL DISCONTINUITY OF 10 μs.
② CONTACT RESISTANCE: 100 m MAX.
VIBRATION
SHOCK
FREQUENCY AT 20 TO 200 Hz,
ACCELERATION AT 43.1 m/s2 FOR 3h ON EACH
3 DIRECTIONS.
-
-
X
③
NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
① NO ELECTRICAL DISCONTINUITY OF 10 μs.
② CONTACT RESISTANCE: 100 m MAX.
FREQUENCY AT 20 TO 50 Hz,
-
-
X
ACCELERATION AT 66.6 m/s2 FOR 1h.
③
NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
APPLY A PULL FORCE WITH 98N MAX ON THE
DIRECTION OF MATING AXIS.
X
① MATING COMPLETELY DURING THE TEST.
② AFTER APPLYING, NO DEFECT ON MATING
PARTS.
LOCK STRENGTH
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
① CONTACT RESISTANCE: 100 m MAX.
② INSULATION RESISTANCE:100 M MIN.
EXPOSE AT 60 C, RH:90 ~ 95 % FOR 500h.
-
X
X
-
-
-
(STEADY STATE)
③
NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
① CONTACT RESISTANCE: 100 m MAX.
② INSULATION RESISTANCE:100 M MIN.
TEMPERATURE- 40 →ROOM TEMP →85℃→
ROOM TEMP
THERMAL SHOCK
-
X
X
-
-
-
③
NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
TIME
30 →
5 → 30 → 5 min
UNDER 1000 CYCLES.
DRY HEAT
EXPOSE AT 105C FOR 300 h.
EXPOSE AT -40C FOR 120 h.
EXPOSED IN 25 ppm FOR 96h.
① CONTACT RESISTANCE: 100 m MAX.
-
-
-
X
②
NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
COLD
① CONTACT RESISTANCE: 100 m MAX.
-
X
-
-
-
-
②
NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
① CONTACT RESISTANCE: 100 m MAX.
② NO HEAVY CORROSION.
-
-
RESISTANCE TO SO2 GAS
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
(NOTE1)
REMARK
KI.HIROKAWA
MO.OKADA
18.06.06
18.06.06
18.06.05
18.06.05
APPROVED
CHECKED
DESIGNED
DRAWN
INCLUDING THE TEMPERATURE RISING DUE TO CURRENT FLOW.
CONTACT RESISTANCE OF OUTER CONDUCTOR AFTER ENVIRONMENTAL AND
DURABILITY TEST IS 150mΩMAX.
(NOTE2)
MH.YAMAGUCHI
DS.HIROWATARI
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-355360-00-00
GT36-4/1S-HU(B)-A
SPECIFICATION SHEET
1/1
HIROSE ELECTRIC CO., LTD.
0
△
CL786-0066-2-00
FORM HD0011-2-1