描述
125 Watt Global Performance Switchers

GPFC125E 数据手册

 浏览型号GPFC125E的Datasheet PDF文件第2页 
GPFC125 Commercial/GPFM125 Medical  
125 Watt Global Performance Switchers  
FEATURES:  
• Compact 125 watt multiple output  
• Power density of 4 watts per cubic inch  
• Power Factor Correction to meet EN61000-3-2  
• Small package 6.00 x 3.5 x 1.5 inches  
• Conducted EMI exceeds FCC Class B and CISPR 22  
Class B (Commercial models) and CISPR 11 Class B  
(Medical models)  
• Commercial approved to UL1950, IEC950, CSA22.2  
No. 950 and EN60950.  
• Medical approved to UL2601-1, IEC601-1, CSA22.2  
No. 601.1, EN60601-1  
marked to LVD  
SPECIFICATIONS:  
Ac Input  
90-264 Vac, 47-63 Hz single phase.  
Remote Sense  
Provided as a standard feature on V1 of all models.  
Input Current  
Temperature Range  
Maximum input current 2A at 90 Vac, 60 Hz with full rated load.  
Input current harmonic content meets the requirements of  
IEC1000-3-2. Active circuitry provides high power factor as  
listed at .96 min., .99 typical. All data taken with full output  
loading.  
0 to 50 °C at full rated output power. For operation above 50 °C,  
derate output power and current by 2.5 % per °C.  
Altitude  
Operating:  
-500 to 10,000 ft. MSL  
Non-Operating -500 to 40,000 ft MSL  
Shock andVibration  
All models are designed to meet the following specifications;  
DC Output Power  
125 W with 150 LFM of air, 50 W convection cooled, 80 W  
convection cooled with unit mounted to min. 12 x 12 x .125 in.  
thick aluminim plate. Peak ratings are for 60 s maximum  
duration, 10% duty cycle. With optional cover installed,125 W,  
200 LFM airflow is required(-C suffix).  
Random Vibration -  
Operating: 0.003 g2/Hz, 1.5 grms overall, 3 axes, 10 min. / axis  
Non-Operating: 0.026 g2/Hz, 5.0 grms overall, 3 axes, 1 hr. / axis  
Shock -  
Inrush Current  
Inrush 240 Vac is less than 37 A, averaged over the first ac  
half-cycle under cold start conditions. Limiting provided by  
internal thermistors.  
Operating: Half-sine, 20 gpk, 10 ms, 3 axes, 6 shocks total  
Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total  
Input Protection  
EMI/EMC Compliance  
Internal ac fuse provided on all models. Fuse does not blow on  
overload or short circuit — fuse blows only if a catastrophic  
failure occurs in the unit.  
All models include built-in EMI filtering to meet the EMC  
requirements below.  
EMI SPECIFICATIONS  
COMPLIANCE LEVEL  
Efficiency  
Conducted Emissions-GPFC125  
Conducted Emissions-GPFM125  
Static Discharge  
RF Field Susceptibility  
Fast Transients / Bursts  
Surge Susceptibility  
Conducted RF Susceptibility  
Voltage Sags & Surges  
Line Frequency Harmonics  
EN55022, Class B; FCC Class B  
EN55011,Class B; FCC Class B  
EN61000-4-2, 6 kV contact 8 kV air  
EN61000-4-3, 3V/meter  
EN61000-4-4, 2 kV, 5 kHz  
EN61000-4-5, 1 kV diff., 2 kV com.  
EN61000-4-6, 3V  
72 to 85% at full rated load. Depending upon model and load  
distribution.  
Minimum Load  
Supply will function with no load on any output. To maintain  
regulation with full load on V2, 3 and 4 output V1 requires a  
minimum load of (2A + V4 current). Lower minimum load may be  
obtained if less then full load is drawn from auxiliary outputs.  
EN61000-4-11  
EN61000-3-2 Class A  
Overload Protection  
Fully protected against short circuit and output overload. Total  
output power limited to approximately 150 Watts. Cycling type  
limits on output 1, 2 & 3, linear fold back on output 4. Recovery  
after fault is automatic.  
Overvoltage Protection  
Built in on all models - See Output table for individual model  
output limits.  
Commercial Safety Approvals  
All models are approved to UL1950, CSA22.2 No. 950-95,  
IEC950, EN60950. CB certificate available. Exceeds FCC and  
CISPR22 Class B conducted emissions requirement  
Medical Safety Approvals  
All models are Certified to be in compliance with the applicable  
requirements of UL2601, CSA 22.2 No. 601.1-M90, IEC 601-1  
(1988), EN 60601-1: 1990. CB certificate available.  
Leakage Current  
The maximum leakage current is as follows:  
Output Noise  
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode.  
Transient Response  
500 ms typical response time for return to within 0.5% of final  
value for a 50% load step change, i/t< 0.2 A ms. Maximum  
voltage deviation is 3.5%.  
Test Condition  
132 Vac @ 60 Hz input  
264 Vac @ 50 Hz input  
Normal  
70 µA  
130 µA  
Single Fault  
120 µA  
240 µA  
Temperature Coefficient  
0.03% / °C typical on all outputs.  
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033  
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com  
52  

与GPFC125E相关器件

型号 品牌 获取价格 描述 数据表
GPFC125F SLPOWER

获取价格

125 Watt Global Performance Switchers
GPFC125G SLPOWER

获取价格

125 Watt Global Performance Switchers
GPFC125H SLPOWER

获取价格

125 Watt Global Performance Switchers
GPFC160 SLPOWER

获取价格

160 Watt Global Performance Switchers
GPFC160-12 SLPOWER

获取价格

160 Watt Global Performance Switchers
GPFC160-12G SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 160W
GPFC160-15 SLPOWER

获取价格

160 Watt Global Performance Switchers
GPFC160-24 SLPOWER

获取价格

160 Watt Global Performance Switchers
GPFC160-28 SLPOWER

获取价格

160 Watt Global Performance Switchers
GPFC160-48 SLPOWER

获取价格

160 Watt Global Performance Switchers