描述
250 Watt Global Performance Switchers

GPFC250-3.3 技术参数

生命周期:Obsolete包装说明:,
Reach Compliance Code:unknown风险等级:5.84
其他特性:REMOTE SHUTDOWN模拟集成电路 - 其他类型:AC-DC REGULATED POWER SUPPLY MODULE
认证:CSA, EN, IEC, UL效率(主输出):75%
高度:44.45 mm最大输入电压:264 V
最小输入电压:85 V长度:203.2 mm
最高工作温度:50 °C最低工作温度:
最大输出电流:50 A标称输出电压:3.3 V
保护:OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE; THERMAL子类别:Power Supply Modules
最大总功率输出:250 W宽度:127 mm
Base Number Matches:1

GPFC250-3.3 数据手册

 浏览型号GPFC250-3.3的Datasheet PDF文件第2页 
GPFC250 Commercial/GPFM250 Medical  
250 Watt Global Performance Switchers  
GLOBAL PERFORMANCE SWITCHERS  
FEATURES:  
• 3.6 watts/cu.in. power density  
• Compact size (5.0” x 8.0” x 1.75”)  
• Power factor corrected to IEC 1000-3-2, Class A  
• Less than 300 μA leakage  
• Conducted EMI exceeds FCC Class B and CISPR 22 Class B  
(Commercial models) and CISPR 11 Class B (Medical models)  
• Commercial Approved to UL1950, IEC950, EN60950 and  
CSA 22.2 No. 950  
• Medical Approved to UL2601-1, IEC601-1/60601-1 and  
CSA-C22.2 No. 601.1  
• 2-year warranty  
• RoHS Compliant Model Available (G suffix)  
SPECIFICATIONS  
Ac Input  
EMI/EMC Compliance  
All models include built-in EMI filtering to meet emissions requirements:  
85-264 Vac, 47-63 Hz single phase.  
Input Current  
EMI SPECIFICATIONS  
COMPLIANCE LEVEL  
Maximum input current 3.7 A at 90 Vac, 60 Hz with full rated load. Input cur-  
rent harmonic content meets the requirements of IEC1000-3-2 Class A for all  
load conditions.  
Conducted Emissions GPFC250  
Conducted Emissions GPFM250  
Static Discharge  
RF Field Susceptibility  
Fast Transients/Bursts  
EN55022 Class B; FCC Class B  
EN55011 Class B: FCC Class B  
EN61000-4-2, 6 kV contact, 8 kV air  
EN61000-4-3, 3 V/meter  
EN61000-4-4, 2 kV, 5 kHz  
EN61000-4-5, 1 kV diff., 2 kV com.  
Hold-upTime  
25 ms minimum from loss of ac input at full load, nominal line (115 Vac).  
Minimum Load: No minimum load required  
Surge Susceptibility  
Output Power  
Inrush Current  
250 W fan cooled, 180 W convection. See chart for models under 12 V.  
Inrush 240 Vac is less than 37 A, averaged over the first ac half-cycle under cold  
start conditions. Limiting provided by internal thermistors.  
Overload Protection  
Fully protected against short circuit and output overload. Short circuit protec-  
tion is cycling type power limit or foldback type depending on model and  
output. Recovery after fault is automatic. Individual output current limits are  
a function of load distribution and degree of overload.  
Fan Output  
An additional 12 Vdc, 250 mA output suitable for powering a dc fan is included in  
all models.  
Thermal Shutdown  
Output Noise  
Provided as a standard feature. Designed to protect unit from prolonged over  
temperature.  
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with  
noise probe directly across output terminals of the power supply.  
Power Fail  
Transient Response  
TTL or CMOS compatible output goes low (<0.5 V) 8 ms before output voltage  
drops more than 4% below nominal voltage upon loss of ac power. The signal is  
factory set to trip when input power can no longer sustain the output.  
Main Output–500 μs typical response time for return to within 0.5% of final  
value for a 50% load step change, Di/Dt< 0.2 A/μs. Maximum voltage devia-  
tion is 3.5%.  
Temperature Coefficient  
0.03% / °C typical on all outputs.  
Remote Sense  
Provided as a standard feature. Capable of compensating for 0.25 V total of  
cabling losses in voltage.  
Leakage Current  
70μA under normal conditions (132 Vac @ 60 Hz).  
Maximum under single fault conditions (264 Vac @ 60Hz), 250 μA.  
Overvoltage Protection  
Built in on all models. Output voltage decay is dependent upon loading.  
Power Good  
Voltage Adjustment  
Main output 5%.  
TTL/CMOS compatible output goes high more than 100 ms after V1 reaches the  
under voltage threshold and should assure that sufficient energy is stored in the  
input  
section to provide normal power fail/shutdown. The signal will fall to a low state  
(<0.5 V) when V1 goes below 95% of the rated voltage.  
Efficency  
Minimum 80% on 12-48 V units, 75% on 5 & 3.3 V units at full rated load.  
Input Protection  
External Off  
Internal ac fuses provided on all models. Fuses do not blow on overload or  
short circuit—fuses blow only if catastrophic failure occurs in the unit.  
TTL/CMOS compatible input shuts down power converter. A logic high (>2.7 V  
with 400 uA source) shuts down the power converter. A logic low (<0.5 V) or an  
open circuit allows the supply to run. 3.3 V & 5 V models require 25 mA source.  
All specifications are typical at nominal input, full load at 25OC unless otherwise stated  

与GPFC250-3.3相关器件

型号 品牌 获取价格 描述 数据表
GPFC250-48 SLPOWER

获取价格

250 Watt Global Performance Switchers
GPFC250-48-CG SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 250W
GPFC250-48G SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 250W,
GPFC250-5 SLPOWER

获取价格

250 Watt Global Performance Switchers
GPFC250-5-C SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 250W
GPFC250-5-CG SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 250W
GPFC250-5G SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 250W,
GPFM115 SLPOWER

获取价格

115 Watt Global Performance Switchers
GPFM115-12 SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 115W
GPFM115-12-CG SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 115W