5秒后页面跳转
GPFC110-28 PDF预览

GPFC110-28

更新时间: 2024-11-05 12:06:51
品牌 Logo 应用领域
SLPOWER /
页数 文件大小 规格书
2页 363K
描述
110 Watt Global Performance Switchers

GPFC110-28 技术参数

生命周期:ObsoleteReach Compliance Code:unknown
风险等级:5.76其他特性:REMOTE SHUTDOWN
模拟集成电路 - 其他类型:AC-DC REGULATED POWER SUPPLY MODULE认证:CE, CSA, EN, IEC, TUV, UL
高度:41.15 mm最大输入电压:264 V
最小输入电压:85 V长度:160.02 mm
最高工作温度:50 °C最低工作温度:
最大输出电流:3.9 A标称输出电压:28 V
保护:OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE子类别:Power Supply Modules
最大总功率输出:110 W宽度:95.25 mm
Base Number Matches:1

GPFC110-28 数据手册

 浏览型号GPFC110-28的Datasheet PDF文件第2页 
GPFC110 Commercial  
110 Watt Global Performance Switchers  
110 WATT GLOBAL PERFORMANCE SWITCHERS  
FEATURES:  
• 3.1 watts/cu.in. power density  
• Compact size (6.3” x 3.75” x 1.62”;  
meets 1U height)  
• Power factor corrected to IEC 1000-3-2 Class A  
• Less than 300 μA leakage  
• EMI compliance to CISPR 22, FCC Class B  
• Approved to UL1950, IEC950 and  
CSA 22.2 No. 950  
• 2-year warranty  
marked to LVD  
• RoHS Compliant Model Available (G suffix)  
SPECIFICATIONS  
EMI/EMC Compliance  
All models include built-in EMI filtering to meet the EMC requirements below.  
Ac Input  
85-264 Vac, 47-63 Hz single phase.  
Input Current  
EMI SPECIFICATIONS  
COMPLIANCE LEVEL  
Maximum input current 2.3 A at 90 Vac, 60 Hz with full rated load. Input cur-  
rent harmonic content meets the requirements of IEC1000-3-2.  
Conducted Emissions  
Static Discharge  
RF Field Susceptibility  
Fast Transients/Bursts  
Surge Susceptibility  
Line Frequency Harmonics  
EN55022 Class B; FCC Class B  
EN61000-4-2, 6 kV contact, 8 kV air  
EN61000-4-3, 3 V/meter  
EN61000-4-4, 2 kV, 5 kHz  
EN61000-4-5, 1 kV diff., 2 kV com.  
EN61000-3-2 Class A  
Hold-up Time  
25 ms minimum from loss of ac input at full load, nominal line (115 Vac).  
Output Power  
110 W fan cooled, 75 W convection. Peak ratings are for 60 s maximum dura-  
tion, 10% duty cycle.  
Inrush Current  
Total Regulation  
Inrush 240 Vac is less than 37 A, averaged over the first ac half-cycle under cold  
start conditions. Limiting provided by internal thermistors.  
Total regulation is the maximum deviation from the nominal voltage for all  
steady-state loading conditions.  
Fan Output  
Overload Protection  
An additional output, same as Vout, suitable for powering a dc fan is included in all  
models. The output is protected by an internal resistor in the event of an overload.  
Fully protected against short circuit and output overload. Short circuit protec-  
tion is cycling type power limit. Recovery after fault is automatic.  
Output Noise  
Power Fail  
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with  
noise probe directly across output terminals of the power supply.  
TTL or CMOS compatible output goes low (<0.5 V) 8 ms before output voltage  
drops more than 4% below nominal voltage upon loss of ac power. The signal is  
factory set to trip when input power can no longer sustain the output.  
Transient Response  
500 μs typical response time for return to within 0.5% of final value for a 50%  
load step change, ∆i/∆ t< 0.2 A/μs. Maximum voltage deviation is 3.5%. Load  
must not go below stated minimum.  
Temperature Coefficient  
0.03%/°C typical on all outputs.  
Environmental  
Remote Sense  
Designed for 0 to 50°C operation at full rated output power; derate output current  
and total output power by 2.5% per °C above 50°C. See Environmental and Pack-  
aging Specifications on the next page.  
Provided as a standard feature. Capable of compensating for 0.25 V total of  
cabling losses in voltage. Open sense lead protection.  
Overvoltage Protection  
OVP crowbar reduces output voltage below nominal rating in less than 50 ms.  
Commercial Safety Approvals  
All models are approved to UL1950, CSA22.2 No. 950-95, IEC950, EN60950. CB  
certificate available. Exceeds FCC and CISPR22 Class B conducted emissions  
requirement  
Voltage Adjustment: Main output 5%.  
Input Protection  
Internal ac fuse provided on all models. Fuse does not blow on overload or  
short circuit—fuse blows only if catastrophic failure occurs in the unit.  
All specifications are typical at nominal input, full load at 25OC unless otherwise stated  

与GPFC110-28相关器件

型号 品牌 获取价格 描述 数据表
GPFC110-28G SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 110W
GPFC110-48 SLPOWER

获取价格

110 Watt Global Performance Switchers
GPFC110-5 SLPOWER

获取价格

110 Watt Global Performance Switchers
GPFC125 SLPOWER

获取价格

125 Watt Global Performance Switchers
GPFC125A SLPOWER

获取价格

125 Watt Global Performance Switchers
GPFC125B SLPOWER

获取价格

125 Watt Global Performance Switchers
GPFC125C SLPOWER

获取价格

125 Watt Global Performance Switchers
GPFC125D SLPOWER

获取价格

125 Watt Global Performance Switchers
GPFC125E SLPOWER

获取价格

125 Watt Global Performance Switchers
GPFC125F SLPOWER

获取价格

125 Watt Global Performance Switchers