Low Voltage Supplementary Fuses
In-line non-rejecting fuses and fuse holders
GLR
GMF
GRF
Specifications
Class: Supplemental
Description: Fast-acting,
non-rejection, in-line fuse.
Construction: Glass tube.
Ratings:
Specifications
Class: Supplemental
Description: Time-delay, non-rejec-
tion, in-line fuse.
Construction: Glass tube.
Ratings:
Volts — 300Vac (or less)
Amps — ⁄16-15A
3
Volts — 300Vac (or less)
Amps — ⁄10-10A
IR — 10,000A
3
Agency Information: CE, Std. 248-14, UL Listed, 0-
15A/300Vac (Guide JDYX, File E19180), CSA Certified,
0-10A/300V (Class 1422-01, File 53787).
IR — 10,000A
Agency Information: CE, Std. 248-14 0-10A, UL Listed
(Guide JDYX, File E19180), CSA Certified, (Class 1422-01,
File 53787).
Features and Benefits
• In-line, fast-acting circuit protection.
Features and Benefits
Typical Applications
• In-Line Lighting Ballast Protection
• In-line, time-delay circuits protection.
Typical Applications
• In-Line Lighting Ballast Protection
Catalog Numbers (Amps) and Non-Rejection Holders
1, 2
1, 2
Fuse
Holder
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
Fuse
Holder
HLR
HLR
HLR
HLR
HLR
HLR
HLR
GLR-3⁄16
GLR-5
GLR-6
GLR-7
GLR-8
GLR-9
GLR-10
GLR-12
GLR-15
Catalog Numbers (-Amps) and Non-Rejection Holders
GLR-1⁄
2
1, 2
1, 2
Fuse
Holder
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
Fuse
Holder
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
GMF-3⁄10
GMF-3
GMF-3
GMF-4
GMF-5*
GMF-6
GMF-10
GRF-7
GRF-8
GLR-1
GLR-11⁄
GLR-16⁄10
GLR-2
2
GMF-1⁄
2
⁄
2
10
GMF-6⁄10
GMF-8⁄10
GMF-1
1
GLR-3
GLR-4
⁄
4
1
HLR-2A
GMF-1 ⁄
GMF-1 ⁄10
GMF-2
GMF-2
GMF-2
4
6
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-
01, File 47235 12A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip
(BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of
thickness 0.043”to 0.062” or #4909 for thickness 0.030” to 0.042”.
1
⁄2
⁄10
GRF-10
8
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File
47235 12A, 300Vac.
* For two leads order HLR-2A, 15A, 300V
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in
a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or
#4909 for thickness 0.030” to 0.042”.
•
An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes
WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line
side receptacle as well as into the load side receptacle. It has the same body
dimensions, utilizes the same mounting hole, and takes the same mounting clips as
the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File
E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235.
*For two leads order HLR-2A, 15A, 300V
•
An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes WITHOUT
leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well
as into the load side receptacle. It has the same body dimensions, utilizes the same mounting
hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A,
300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235.
Do not put tension on line (rear) terminal of fuse holder.
•
Do not put tension on line (rear) terminal of fuse holder.
•
*HLR Fuse Holder
for both GMF & GRF fuses.
Data Sheet: 2032
Data Sheet: 2031
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
52