G3VM-401BY/EY
MOS FET Relays
Analog-switching MOS FET Relays with
a Dielectric Strength of 5 kVAC between
I/O Using Optical Isolation.
• Switches minute analog signals.
• Leakage current of 1 µA max. when output relay is open.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■
Terminal Arrangement/Internal Connections
6
5
4
• Communication equipment
• Test & Measurement equipment
• Industrial equipment
OMRON logo
Pin 1 mark
Model name
LOT.NO.
932
1
2
3
Note: The actual product is marked differently from the image shown here.
■ List of Models
Minimum package quantity
Model
Load voltage
(peak value) *
Package type Contact form
Terminals
Number per tube Number per tape and reel
PCB Terminals
G3VM-401BY
50
-
-
1a
DIP6
400 V
G3VM-401EY
(SPST-NO)
Surface-mounting Terminals
G3VM-401EY (TR)
1,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Symbol
IF
Rating
50
1
−0.5
5
125
400
120
120
240
Unit
mA
A
Measurement conditions
Note: 1. The dielectric strength between the input and output was
checked by applying voltage between all pins as a group on
the LED side and all pins as a group on the light-receiving side.
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Connection A
IFP
100 µs pulses, 100 pps
Connection Diagram
∆IF/°C
VR
mA/°C Ta ≥ 25°C
V
°C
V
1
2
3
6
5
4
Load
TJ
Connection A
Connection B
Connection C
or AC
DC
VOFF
Continuous
Connection B
Connection A: AC peak/DC
Connection B and C: DC
IO
mA
load current
Connection C
1
2
3
6
5
4
Load
DC
Connection A
Connection B
Connection C
−1.2
−1.2
−2.4
125
ON current
reduction
rate
∆IO/°C
mA/°C Ta ≥ 25°C
°C
Vrms
°C
Connection temperature
Dielectric strength between I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
TJ
VI-O
Ta
1
2
3
6
5
4
Load
DC
5000
−40 to +85
−55 to +125
260
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Tstg
-
°C
°C
■ Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical Maximum Unit
Measurement conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IO = 120 mA
IF = 5 mA, IO = 120 mA
IF = 5 mA, IO = 120 mA
IF = 5 mA, IO = 240 mA
VOFF = 400 V
V = 0, f = 1 MHz
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60%
IF = 5 mA, RL = 200 Ω,
VDD = 20 V(See note 2.)
LED forward voltage
Reverse current
Capacity between terminals
Trigger LED forward current
Maximum
resistance
VF
IR
CT
IFT
1.0
-
-
-
-
-
-
-
1.15
-
30
-
17
11
6
1.3
10
-
V
µA
pF
mA
Ω
Note: 2. Turn-ON and Turn-OFF Times
IF
1
6
RL
3
VDD
VOUT
Connection A
Connection B
Connection C
35
20
10
1.0
-
2
4
RON
Ω
with output ON
Ω
Current leakage when the relay is open
Capacity between terminals
Capacity between I/O terminals
Insulation resistance between I/O terminals
Turn-ON time
ILEAK
COFF
CI-O
RI-O
tON
-
µA
pF
pF
MΩ
ms
ms
-
40
0.8
-
IF
-
-
1000
-
90%
VOUT
10%
-
-
0.3
0.1
1.0
1.0
tON
tOFF
Turn-OFF time
tOFF
1