G3VM-@CR@/@FR@
MOS FET Relays DIP 8-pin, High-Current and Low-ON-resistance Type
The highest class load current of
MOS FET Relays realized with
DIP8 package
• Contact form: 1a (SPST-NO)
• Load voltage: 60 V, 100 V, 200 V, 400 V, or 600 V
• 60-V Relay: Continuous load current of 5 A (10 A) max. *
• 100-V Relay: Continuous load current of 3 A (6 A) max. *
• 200-V Relay: Continuous load current of 1.5 A (3 A) max. *
Note: The actual product is marked differently from the
• 400-V Relay: Continuous load current of 0.4 A (0.8 A) max. *
image shown here.
• 600-V Relay: Continuous load current of 0.6 A (1.2 A) max. *
* Values in parentheses are for connection C.
RoHS Compliant
■Application Examples
• Communication equipment
• Industrial equipment
• Test & Measurement equipment
• Power circuit
• Security equipment
■Package (Unit : mm, Average)
■Model Number Legend
DIP 8-pin
G3VM-@ @ @ @ @
PCB Terminals
1 2 3 4
5
1. Load Voltage
2. Contact form
3. Package
6 : 60 V
1 : 1a (SPST-NO)
C : DIP 8-pin with PCB terminals
F : DIP 8-pin with surface-mounting
terminals
10 : 100 V
20 : 200 V
40 : 400 V
60 : 600 V
Surface-mounting Terminals
4. Additional functions
5. Other informations
R: Low ON resistance
When specifications overlap, serial code is
added in the recorded order.
Note: The actual product is marked differently
from the image shown here.
■Ordering Information
Stick packaging
Model
Surface-mounting
Tape packaging
Load voltage
(peak value)
Contact
form
Continuous load current
Model
Minimum
package
quantity
Minimum
Package
(peak value) *
package
quantity
Surface-mounting
Terminals
*
PCB Terminals
Terminals
60 V
5 A
3 A
G3VM-61CR1
G3VM-101CR
G3VM-201CR
G3VM-401CR
G3VM-601CR
G3VM-61FR1
G3VM-101FR
G3VM-201FR
G3VM-401FR
G3VM-601FR
G3VM-61FR1(TR05)
G3VM-101FR(TR05)
G3VM-201FR(TR05)
G3VM-401FR(TR05)
G3VM-601FR(TR05)
100 V
200 V
400 V
600 V
1a
DIP8
1.5 A
0.4 A
0.6 A
50 pcs.
500 pcs.
(SPST-NO)
* The AC peak and DC value are given for the load voltage and continuous load current.
Note: To order tape packaging for Relays with surface-mounting terminals, add “(TR05)” to the end of the model number.