Power Entry Modules with Line Filter
FKH
www.schurter.com/pg06
IEC Appliance Inlet C14 with Filter, Fuseholder 1-pole, Line Switch 2-pole
Standard- or Medical-Filter
on phase-out
C14
70° C
Description
Characteristics
-ꢀPanelꢀMount:
-ꢀCompactꢀdesignꢀwithꢀoptimalꢀshielding
-ꢀAllꢀsingleꢀelementsꢀareꢀalreadyꢀwired
-ꢀPlugꢀremovalꢀnecessaryꢀforꢀfuse-linkꢀreplacement
ꢀ Screw-onꢀmountingꢀfromꢀfrontꢀsideꢀ
-ꢀ4ꢀFunctions:
ꢀ Ifꢀtheꢀpowerꢀentryꢀmoduleꢀisꢀinstalledꢀasꢀnormal,ꢀitꢀisꢀnotꢀpossibleꢀtoꢀ
touchꢀanyꢀliveꢀpartsꢀwithꢀtheꢀtest-fingerꢀaccordingꢀtoꢀIEC60529
ꢀ FuseꢀdrawerꢀmeetsꢀrequirementsꢀofꢀmedicalꢀstandardꢀIEC/ENꢀ60601-1
ꢀ Theꢀfuseholderꢀisꢀaccessibleꢀfromꢀtheꢀequipmentꢀfront
-ꢀWithꢀEMC-shield
ꢀ ApplianceꢀInletꢀProtectionꢀclassꢀI,ꢀLineꢀSwitchꢀ2-pole,ꢀFuseholderꢀforꢀ
fuse-linksꢀ5ꢀxꢀ20ꢀmmꢀ1-pole,ꢀLine-filterꢀinꢀstandardꢀversionꢀ
-ꢀQuickꢀconnectꢀterminalsꢀ6.3ꢀxꢀ0.8ꢀmm
Approvals
-ꢀVDEꢀLicenseꢀNumber:ꢀ40004665
-ꢀULꢀLicenseꢀNumber:ꢀE72928
-ꢀQualifiedꢀforꢀuseꢀinꢀequipmentꢀaccordingꢀIEC/ENꢀ60950
Other versions on request
-ꢀMedicalꢀversionꢀM80
References
GeneralꢀProductꢀInformation
Weblinks
Approvals,ꢀRoHS,ꢀCHINA-RoHS,ꢀMatingꢀConnectors,ꢀDistributor-Stock-
Check,ꢀAccessories
Technical Data
RatingsꢀIEC
1ꢀ-ꢀ10ꢀAꢀ@ꢀTaꢀ40ꢀ°Cꢀ/ꢀ250ꢀVAC;ꢀ50ꢀHz
1ꢀ-ꢀ10ꢀAꢀ@ꢀTaꢀ40ꢀ°Cꢀ/ꢀ125ꢀVAC;ꢀ60ꢀHz
standardꢀ<ꢀ0.25ꢀmAꢀ(250ꢀVꢀ/ꢀ60ꢀHz)
>ꢀ1.7ꢀkVDCꢀbetweenꢀL-Nꢀ
>ꢀ2.7ꢀkVDCꢀbetweenꢀL/N-PEꢀ
Testꢀvoltageꢀ(2ꢀsec)
Appliance-Inlet/-Outlet
Fuseholder
C14ꢀacc.ꢀtoꢀIEC/ENꢀ60320-1,ꢀ
ULꢀ498,ꢀCSAꢀC22.2ꢀno.ꢀ42ꢀ(forꢀcoldꢀ
conditions)ꢀpin-temperatureꢀ70ꢀ°C,ꢀ10ꢀA,ꢀ
ProtectionꢀClassꢀ1
1-pole,ꢀShocksafeꢀcategoryꢀPC2ꢀacc.ꢀtoꢀ
IECꢀ60127-6,ꢀ
RatingsꢀUL/CSA
LeakageꢀCurrent
DielectricꢀStrength
forꢀfuse-linksꢀ5ꢀxꢀ20ꢀmm
AllowableꢀOperationꢀTemp.
ClimaticꢀCategory
DegreeꢀofꢀProtection
ProtectionꢀClass
-25ꢀ°Cꢀtoꢀ85ꢀ°C
RatedꢀPowerꢀAcceptanceꢀ@ꢀ 5ꢀxꢀ20:ꢀ1.6ꢀWꢀ(1ꢀpole)
Taꢀ23ꢀ°C
PowerꢀAcceptanceꢀ@ꢀTaꢀ>ꢀ
23°C
25/085/21ꢀacc.ꢀtoꢀIECꢀ60068-1
fromꢀfrontꢀsideꢀIPꢀ40ꢀacc.ꢀtoꢀIECꢀ60529
Suitableꢀforꢀappliancesꢀwithꢀprotectionꢀ
classꢀ1ꢀacc.ꢀtoꢀIECꢀ61140
Quickꢀconnectꢀterminalsꢀ6.3ꢀxꢀ0.8ꢀmm
Screw:ꢀmaxꢀ8ꢀmmꢀ
Admissibleꢀpowerꢀacceptanceꢀatꢀhig-
herꢀambientꢀtemperatureꢀseeꢀderatingꢀ
curves
Rockerꢀswitchꢀ2-pole,ꢀnon-illuminated,ꢀ
acc.ꢀtoꢀIECꢀ61058-1ꢀ
Technicalꢀdetails
StandardꢀVersion,ꢀIECꢀ60939,ꢀIECꢀ
60601-1,ꢀULꢀ1283,ꢀULꢀ544,ꢀENꢀ133ꢀ
200,ꢀCSAꢀC22.2ꢀno.ꢀ8ꢀ
Terminal
PanelꢀThicknessꢀs
LineꢀSwitch
LineꢀFilter
Mountingꢀscrewꢀtorqueꢀmaxꢀ0.5ꢀNm
Thermoplastic,ꢀblack,ꢀULꢀ94V-0
Material:ꢀHousing
Technicalꢀdetails
MTBF
>ꢀ1'700'000ꢀhꢀacc.ꢀtoꢀMIL-HB-217ꢀF
EMC Products
ꢀ