APPLICABLE STANDARD
UL approved(E481344)
1
△
OPERATING TEMPERATURE
STORAGE TEMPERATURE
-20 C TO +105 C
-10 C TO +60 C
(Including temperature rise due to conduction)
RANGE
RANGE
RATING
VOLTAGE
CURRENT
AC,DC 1000V
42.42 TO 60.57 mm2
AWG 1
APPLICABLE CABLE
200 A (NOTE4)
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X
MARKING
ELECTRIC CHARACTERISTICS
X
X
CONTACT RESISTANCE
MEASURED AT THE CONTACT AT DC 1A.
0.6mΩ MAX.
INSULATION RESISTANCE
VOLTAGE PROOF
X
X
MEASURED AT DC 500V.
1000MΩ MIN.
―
―
AC 2200V APPLIED FOR 1min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONNECTOR INSERTION AND
MEASURED WITH AN APPLICABLE CONNECTOR
INSERTION AND WITHDRAWAL FORCES: 100N MAX.
NO DAMAGE
X
X
―
―
WITHDRAWAL FORCES
WITHOUT A LOCKING DEVICE.
TERMINAL RETENTION FORCE
MECHANICAL OPERATION
280N APPLIED AT THE CONNECTION
1) NO FUNCTION IMPAIRING DAMAGE, CRACKS, OR
LOOSENESS IN THE PARTS.
2) CONTACT RESISTANCE: 0.8 mΩ MAX.
INSERETED AND EXTRACTED 50 TIMES.
X
―
FREQUENCY RANGE: 10 TO 500Hz/CYCLE,SINGLE AMPLITUDE OF 1) NO ELECTRICAL DISCONUITY OF 10μs.
VIBRATION
SHOCK
0.75mm, FOR 3 HOURS IN 3 AXIAL DIRECTIONS
2) NO DAMAGE, CRACKS, OR LOOSENESS IN THE
X
X
―
―
(MIL-STD-1344 method 2005, condition 2).
IN 6 AXIAL DIRECTIONS AT AN ACCELERATION OF 490 m/s2, 1) NO ELECTRICAL DISCONUITY OF 10μs.
PARTS.
A PULSE DURATION OF 11ms AND PERFORMED 3 TIMES.
2) NO DAMAGE, CRACKS, OR LOOSENESS IN THE
PARTS.
ENVIRONMENTAL CHARACTERISTICS
1) INSULATION RESISTANCE: 10MΩ MIN (WHEN
WET).
DAMP HEAT
TEMPERATURE: 40゚ C, HUMIDITY 90 TO 95%, LEFT FOR 96
HOURS.
2) INSULATION RESISTANCE: 100MΩ MIN (WHEN
DRY).
X
X
―
―
(STEADY STATE)
3) NO DAMAGE, CRACKS, OR LOOSENESS IN THE
PARTS.
TEMPERATURE: -40゚ C → R/T(3) → +105゚ C → R/T
1) INSULATION RESISTANCE: 1000MΩ MIN.
2) NO DAMAGE, CRACKS, OR LOOSENESS IN THE
PARTS.
TEMPERATURE CYCLE
TIME: 30 → 2 TO 3 → 30 → 2 TO 3 min
TESTED OVER 5 CYCLES.
X
X
RESISTANCE TO HEAT
RESISTANCE TO COLD
EXPOSED AT A TEMPERATURE OF +105゚ C FOR 96 HOURS.
EXPOSED AT A TEMPERATURE OF -40゚ C FOR 96 HOURS.
NO DAMAGE, CRACKS, OR LOOSENESS IN THE PARTS.
NO DAMAGE, CRACKS, OR LOOSENESS IN THE PARTS.
―
―
CONNECTED TO AN APPLICABLE CONTACT AT A WATER DEPTH OF
1m FOR 30 MINUTES.
SEALING(2)
NO WATER PENETRATION INSIDE THE CONNECTOR.
NO AIR BUBBLES EMITTED FROM THE CONNECTOR.
X
X
―
―
CONNECTED TO AN APPLICABLE CONTACT, 17.6kPa OF AIR
PRESSURE WAS APPLIED FOR 30 SECONDS.
AIR TIGHTNESS(2)
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
TY.TAKAHASHI
CHECKED
DATE
1
DIS-C-00013440
EJ.KUNII
20221130
1
REMARKS
APPROVED
CHECKED
DESIGNED
DRAWN
TP.KOMATSU
20220520
20220518
20220517
20220516
Notes: (1)
Above specifications show the values in assembled condition with
applicable crimp contacts.
EJ.KUNII
HR.SATO
HR.SATO
(2) R/T = room temperature
For unspecified specifications, refer to IEC 60512 (JIS C 5402).
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-119510-81-00
EM30M-BP-1PCA-K(81)
SPECIFICATION SHEET
1
1/2
△
HIROSE ELECTRIC CO., LTD.
CL0138-0076-0-81
FORM HD0011-2-1