Electric Double Layer Capacitors (Gold Capacitor)
Stacked Coin Type
Series : RG Low temperature assured product
Features
●
Endurance : +85 °C 2000 h
Category temperature range : –40 °C to +85 °C
RoHS compliant
●
●
Recommended applications
●
Backup of data/RTC of base station, electronic meter, and industrial equipment
Specifications
Category temp. range
Maximum operating voltage
Nominal capacitance
–40 °C to +85 °C
ꢀ.6 V.DC
0.22 F
1.0 F, 1.5 F
Capacitance change
Internal resistance
ꢀ0 ꢁ of initial measured value at +20 °C (at –40 °C)
7 times of initial measured value at +20 °C (at –40 °C)
Characteristics at
low temperature
<
After 2000 hours application of maximum operating voltage at +85 °C
Capacitance change
ꢀ0 ꢁ of initial measured value at 20 °C
100 Ω or less (0.22 F)
40 Ω or less (1.0 F, 1.5 F)
Endurance
Shelf life
Internal resistance
After 2000 hours storage at +85 °C without load (voltage)
Capacitance change Capacitance change shall meet the specified limits for Endurance
Internal resistance Internal resistance shall meet the specified limits for Endurance
Dimensions in mm(not to scale)
RG series (0.22 F)
RG series (1.0 F, 1.5 F)
Terminal : V
Terminal : H
Terminal : V
Terminal : H
Sleeve
Sleeve
5.0 max.
10.5 max.
f19.0 0.ꢀ
5.5 0.5
f19.0 0.ꢀ
20.5 Max.
20.0 0.5
11.5 max.
10.0 0.5
0.2 0.05
–
+
5.0 0.8
1.0 0.1
0.8 0.05
5.0 0.5
0.20 0.05
(1.7)
0.2 0.05
1.0 0.1
0.2 0.05
0.8 0.05
(1.7)
(Unit : mm)
Characteristics list
Category Maximum
Internal
resistance
(Initial specified value)
(Ω) at 1 kHz
Min.
packaging
q'ty
Capacitance
tolerance
(F)
Mass
(Reference value)
✽1
temp.
range
(°C)
operating Capacitance
voltage
(V.DC)
Recommended
Parts number
(F)
discharge current
(g)
(pcs)
0.22
1.0
0.176 to 0.ꢀ96
0.8 to 1.8
ꢀ00 µA or less EECRG0V224( )N
1 mA or less EECRG0V105( )N
1 mA or less EECRG0V155( )N
1.0
4.1
4.2
200
100
100
< 50
< 20
< 20
–40 to +85
ꢀ.6
1.5
1.2 to 2.7
( ) : Please use V or H to indicate terminal type.
1 The recommended discharge current is a reference value. Please design your equipment(circuit) in consideration of IR drop.
✽
Do not use reflow soldering. Please refer to the page of “Application guidelines”.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
02 Aug. 2016